Doc No. FM0600 issue I Page 1 

 

169MHz Telecare Devices 

Sensor Controller 

_______________________________________________________________________________________________________________ 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible with Reach at-home alarms, Advent xt warden call,  

Altec Response and Touchsafe Pro Nursecall systems 

 

Can be used for bed or chair occupancy monitoring 

 

Fully configurable with text display menus 

 

Real time clock with auto-BST adjustment 

 

Supplied with mains adapter & rechargeable battery 

 

Dimensions: 190mm x 100mm x 32mm (HxWxD)  

 

Weight: 285 grams (inc battery) 

 

Sensor Controller with standard bed sensor: Product Code ZXT473 

 

Sensor Controller with standard chair sensor: Product Code ZXT474 

 
 

What is the Sensor Controller used for? 

 

The sensor controller is normally used for bed or chair occupancy monitoring; if a person gets into bed/sits in their chair, then gets up 
again and does not return within a preset period an alarm call will be transmitted. Alternatively, the sensor controller can be used with a 
floor pressure mat or a door contact to raise an instant alarm. 

 

 

How does the Sensor Controller work? 

 

The sensor controller is normally supplied with a standard bed or chair sensor as a complete package. The controller and other sensor 
options are also available separately if custom packages are required. 

 

The sensor controller must be installed with a Reach at-home alarm, an Advent xt warden call system, an Altec Response local carer 
alarm unit or a Touchsafe Pro Nursecall system. 

 

The sensor controller has a real time clock with automatic British Summer Time adjustments (i.e. the +/- 1 hour clock changes are made 
automatically on the correct day every March and October).  

 

With a standard bed

 

or chair sensor an alarm can be raised either 

instantly

 a person leaves their bed/chair or after a 1 to 99 minute 

programmable 

absence period

 if the person does not return to their bed/chair. If the person does not return and an alarm is raised but 

they are OK, then an optional 1 to 99 minute programmable 

reset period

 can be set. If the person is not detected back in their bed/chair 

at the end of this period, then an alarm will be raised again. 

 

Monitoring starts when a person has been in their bed/chair for 30 seconds (default 

logged in bed time

). Continuous monitoring is 

possible if the controller is set to be 

on all the time

. Alternatively, up to 

3

 

active periods

 can be programmed to repeat every day. There 

is also the option to raise an alarm if a person is 

not in their bed/chair

 after a 0 to 999 minute programmable delay from the start of the 

monitoring period.  

 

Monitoring will end at the end of each monitoring period unless the 

still in bed/chair

 option is set. This is a 0 to 999 minute 

programmable period – if the person is still in their bed/chair at the end of this period an alarm will be raised. 

 

If the person is going to be away from home for a few days, the Sensor Controller has an 

away mode

 feature which suspends monitoring 

to prevent false alarms. When the person returns home the unit must be switched back into 

home mode

 and normal monitoring will 

resume. 

 

The sensor controller has a 

Carer Call

 button to activate an alarm call at any time. An optional Pear Push lead is available to activate a 

carer call. 

 

With a Magic Stick or SensAlert bed/chair sensor an alarm can be raised either 

instantly

 a person leaves their bed/chair or after a 

programmable 0 to 999 second 

countdown

 delay. The alarm can be cancelled during the countdown by pressing the 

 key. 

 

With a pressure mat or door contact an alarm can be raised either 

instantly

 a person steps on the mat or opens the monitored door or 

after a programmable 0 to 999 second 

countdown

 delay. The alarm can be cancelled during the countdown by pressing the 

 key. 

 

An RJ45 double adapter is used to connect 2 sensors per controller - 

Note: both sensors must be the same type

.  

 

 
 
 
 
 
 
 
 
 

 

Tynetec and Aidcall are business units of Legrand Electric Ltd 

Unit 10 Cowley Road, Blyth Riverside Business Park, Blyth 

Northumberland, NE24 5TF. Tel: 

01670 352 371

 

Fax: 

01670 362 807

 

Email: 

[email protected]

  Web

www.tynetec.co.uk

 

Содержание Tynetec ZXT473

Страница 1: ...d but they are OK then an optional 1 to 99 minute programmable reset period can be set If the person is not detected back in their bed chair at the end of this period then an alarm will be raised agai...

Страница 2: ...CONTROLLER The sensor controller includes a power lead and a rechargeable battery depending on the package it may also be supplied with either a bed sensor or a chair sensor Alternative bed chair sens...

Страница 3: ...Spare Chair Sensor with 2m Lead Product Code ZCS859 Dimensions 325mm x 130mm x 10mm LxWxD RJ45 Double Adapter used to connect 2 chair sensors Product Code P10285 4 HOW TO INSTALL A PRESSURE MAT The Pr...

Страница 4: ...st be placed on top of the mattress below the sheet See the placement options printed on the Bed Sensor Ensure the connecting cable exits safely without causing a trip hazard Plug the lead into the se...

Страница 5: ...another sub menu or give you the option to change settings Use the keys to increase decrease the setting highlighted by the cursor Use the keys to move the cursor back forwards between fields To retu...

Страница 6: ...l end at the end of the monitoring period If you choose Yes the display will change to Still in Bed Alarm How Long 000 Mins Use the keys to set the still in bed alarm from 0 to 999 minutes then press...

Страница 7: ...Setup Exit Select Calibrate and Test then press ENTER Calibrate and Test Calibrate Sensor View In Out States Change Sensitivity Calibrate and Test Test Mode Exit Calibrate Sensor place the bed chair s...

Страница 8: ...d Alarm No Still in Bed Alarm No Low Battery Beep Yes Program ID to enter the last 6 digits from the product label Register Device to learn the unit onto an at home alarm warden call carer call or Nur...

Страница 9: ...digit ID is made up of the 2 digit sensor type code e g bed sensor 33 chair sensor 38 or door exit 34 followed by the 6 digit unit ID which can be found on a label on the back of the sensor controller...

Страница 10: ...Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for m...

Страница 11: ...o FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press the CARER CALL button The display will show the Sensor Type and the sensor controller...

Страница 12: ...leted from the Delete Telecare Device pull down list box prefixed with a T33 34 38 Details of the Sensor Controller selected will be displayed in the Room House Code and ID boxes below If the details...

Страница 13: ...y can be used to raise an instant alarm call via the warden call system at home alarm or Nursecall system When the sensor controller is in its normal operating mode the key is used to send a CARER CAL...

Отзывы: