The XSD1U can be to be mounted to:

a bare concrete wall with a minimum thickness of 

8" (203mm):

a bare 8" x 8" x 16" (203mm x 203mm x 406mm) 

concrete block wall;

wood studs spaced 16" or 24" on center with a 

maximum drywall covering of 5/8”; or

a 2" x 4"-25ga minimum steel stud wall.

a 1/2" minimum thickness plywood-backed, steel stud 

wall covered with drywall having a maximum thickness 

of 5/8".

Installing to Wood Stud Wall

1.

Use a stud-finder to locate 16" or 24" studs.

2.

Place top bracket (B) against wall at desired mounting 

location 10 1/8" above the desired center of the screen. Use 

a level to ensure a level mount. (See Figure 1)

3.

Mark hole locations at each mounting location in the center 

of each stud. (See Figure 1)

4.

Drill two 7/32” holes at marked hole locations. (See Figure 

1)

5.

Install two 5/16 x 2 1/2” hex head cap screws (G) through 

two 5/16" washers (H), holes on top bracket and into drilled 

holes on wall. (See Figure 1)

Figure 1

CAUTION:  

Use proper lifting techniques and two people to 

install XSD1U assembly onto wall!

6.

Carefully hang XSD1U assembly (A) onto top bracket (B), 

making sure mount slides behind upper flange on top 

bracket (B). (See Figure 2)

Figure 2

7.

Remove screw holding bottom cover to XSD1U assembly 

(A) and remove bottom cover. (See Figure 3)

Figure 3

8.

Mark hole locations for lower two mounting holes. (See 

Figure 4)

9.

Remove mount (A) from top bracket.

10. Drill two 7/32” holes at marked hole locations. (See Figure 

4)

Figure 4

3

4

(G) x 2

5

7/32” (5.3mm)

(B)

(H) x 2

(B)

(A)

6

6

7

7

7

x

x

8

10

7/32” (5.3mm)

Содержание CHIEF XSD1U

Страница 1: ...o Istruzioni di installazione Installatie instructies Instructions d installation Lowest position Highest position Electric Height Adjustable Wall Mount Spanish Product Description German Product Description Portuguese Product Description Italian Product Description Dutch Product Description French Product Description XSD1U ...

Страница 2: ...s used by or near children invalids or disabled persons 3 Use this furnishing only for its intended use as described in these instructions Do not use attachments not recommended by the manufacturer 4 Never operate this mounting system if it has a damaged cord or plug if it is not working properly if it has been dropped or damaged or dropped into water Return the mounting system to a service center...

Страница 3: ...uare NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may ...

Страница 4: ...IMENSIONS 20 37 517 4 MAX MIN 7 94 201 6 MAX 33 94 862 10 13 257 2 C L to UPPER MOUNTING POINT 26 76 679 6 40 13 1019 3 100MM 24 00 609 6 16 00 406 4 0 84 21 4 9 98 253 4 12 83 326 0 24 12 612 7 PLUMB 26 94 684 3 12 46 316 4 14 48 367 9 ...

Страница 5: ...have de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perforar ...

Страница 6: ...Bluetooth Remote R 1 1 8 F 4 Concrete anchor Cable tie J 4 1 4 20 Toggler P 1 Control pad A 1 XSD1U assembly C 8 E 1 Bluetooth Dongle S 1 5 64 G 4 5 16 x 2 1 2 K 4 1 4 20 x 2 1 2 L 4 1 4 M 1 6 32 x 3 8 N 2 1 4 20 x 1 2 Control pad bracket Installation Instructions H 1 T 1 Display interface hardware See interface parts list on page 7 U 1 Double sided foam tape 5 16 Concrete Mounting Kit Q 1 Toggler...

Страница 7: ...4 TP 1 1 8 Hardware Kit Bag A Bag B Bag C Bag D Bag E Bag F Bag G Bag H Bag I Bag J Bag K Bag L Bag M TB 4 M4 x 20mm 10 24 x 1 2 M4 x 25mm M5 x 12mm M5 x 20mm M5 x 25mm M6 x 12mm M6 x 20mm M6 x 25mm M8 x 12mm M8 x 20mm M8 x 30mm Vertical bracket Horizontal bracket M4 x 12mm TMA 8 Nesting spacer TMB 4 Universal spacer TN 8 ...

Страница 8: ...ure 1 3 Mark hole locations at each mounting location in the center of each stud See Figure 1 4 Drill two 7 32 holes at marked hole locations See Figure 1 5 Install two 5 16 x 2 1 2 hex head cap screws G through two 5 16 washers H holes on top bracket and into drilled holes on wall See Figure 1 Figure 1 CAUTION Use proper lifting techniques and two people to install XSD1U assembly onto wall 6 Care...

Страница 9: ...ng slot See Figure 6 3 Drill two 3 8 holes at marked hole locations See Figure 6 4 Install a concrete anchor F into each pilot hole using a hammer making sure that the anchor is flush with the wall See Figure 6 5 Install two 5 16 x 2 1 2 hex head cap screws G through two 5 16 washers holes on top bracket B and into concrete anchors F See Figure 6 Figure 6 CAUTION Use proper lifting techniques and ...

Страница 10: ...l See Figure 10 Figure 10 12 Hang wall mount back onto top bracket and install two 5 16 x 2 1 2 hex head cap screws G through two 5 16 washers H lower mounting holes on mount and into concrete anchors See Figure 11 Figure 11 13 Use two 1 4 20 x 1 2 button head cap screws N and 1 8 hex key R to secure mount to wall See Figure 11 Installing to Steel Studs Make sure installation site meets the requir...

Страница 11: ...wall is unfinished drywall must be installed to a minimum of one stud left and right of the stud s being used to install the mount Drywall must be secured to studs with screws a maximum of 12 305mm apart down center of stud Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Members 5 8 maximum drywall thickness Both Sid...

Страница 12: ...e inside wall 16 on center Studs If back side of wall is unfinished drywall must be installed to a minimum of one stud left and right of the studs being used to install the mount Drywall must be secured to studs with screws 12 on center Steel Stud 2 x 4 25ga minimum Stud type and structural strength must conform to the North American Specification for the Design of Cold Formed Steel Structural Mem...

Страница 13: ... wall until flange of cap is flush with wall See Figure 15 Figure 15 7 Snap off plastic straps on anchor at wall by pushing side to side snapping off straps level with flange of plastic cap See Figure 16 8 Repeat Steps 4 through 7 for the other mounting hole Figure 16 9 Place top bracket B over anchors and align mounting holes on mount with holes in anchors See Figure 17 10 Install a toggler ancho...

Страница 14: ...cations for lower two mounting holes See Figure 20 15 Remove mount A from top bracket 16 Drill two 1 2 holes at marked hole locations See Figure 20 Figure 20 17 Install a toggler anchor J into each pilot hole following Steps 4 7 in this section 18 Hang wall mount back onto top bracket and install two 1 4 20 x 2 1 2 Phillips pan machine screws K through lower mounting holes on mount and into toggle...

Страница 15: ...her side top or bottom depending on user preference See Figure 24 NOTE The control pad P may also be installed to the bottom edge of the display using the double sided tape U If this is desired plug the switch directly to port A1 or A2 to initialize and route cable after display is installed Figure 24 6 Use 6 32 x 3 8 button head cap screw M to secure control pad bracket Q to mount See Figure 25 F...

Страница 16: ... to be partially extended in order to re install top cover 14 Re install top cover and tighten button head cap screws to secure it in position See Figure 29 Figure 29 15 Re install bottom cover and secure with removed button head cap screw See Figure 30 Figure 30 Display Installation WARNING Exceeding the weight capacity can result in serious personal injury or damage to equipment It is the instal...

Страница 17: ...play 7 Adjust vertical mounting bracket TR position until mark made in Step 1 aligns with center mark in vertical mounting bracket TR 8 Select correct screws nesting spacers if necessary and universal washers if required from the hardware bag TA TM and attach brackets to back of screen See Figure 34 IMPORTANT The M8 screws do NOT require a washer Use the universal washer TMB only with M4 M5 and M6...

Страница 18: ...U aligns with mark made in Step 11 and mounting holes and slots in horizontal mounting bracket TQ are aligned with threaded holes in mounting tabs of left and right vertical mounting brackets TR See Figure 35 and See Figure 36 15 Use 1 8 hex key TP to secure upper horizontal mounting bracket TQ to left and right vertical mounting brackets TR using four button head flanged screws TN See Figure 36 1...

Страница 19: ...Figure 38 Figure 38 Save Height Levels 1 Adjust height until desired preset level is reached using UP and DOWN buttons See Figure 38 2 Press SAVE button See Figure 38 3 Press one of three preset buttons or to save preset position See Figure 38 4 Repeat Steps 1 3 as desired Leveling Adjustment 1 Adjust leveling adjustment screws through access holes to level mount as desired 3 4 See Figure 39 Figur...

Страница 20: ...osition to ensure cables are installed with enough slack 1 Use cable clips and or cable ties C to route cables as desired See Figure 41 2 Route cables through opening on bottom cover if a power box is not installed behind the mount See Figure 41 and See Figure 42 Figure 41 Figure 42 cable clips 1 2 2 bottom view ...

Страница 21: ...Installation Instructions XSD1U 21 ...

Страница 22: ...XSD1U Installation Instructions 22 ...

Страница 23: ...Installation Instructions XSD1U 23 ...

Страница 24: ...2 225 6000 F 877 894 6918 952 894 6918 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 8800 003066 Rev01 2019 Legrand AV www legrandav com 03 19 ...

Отзывы: