11
OPTION 3: Manual configuration using end-of-line software with a single chair. An end-of-line software
package will be provided to manufacturers that allows the configuration parameters to be downloaded
to the motor controller. This software can also assign an ID. Please see Step 10 for more details.
Step 10: Configuration of Chair
The LP Connect package allows you to programmatically set soft limits, auto-close and other settings.
Instructions are below.
1. An end-of-line software package will be running on a PC. This allows the configuration
parameters to be downloaded to the motor controller.
2. A button will be pressed on the PC software that will download the parameters and may also
run the chair through a self-test, generate a serial number, etc.
The following parameters can be configured:
• Auto-close timer
• Current limit (limits the maximum electrical current that the motor can deliver, preventing
possible damage)
• Soft limit position (limits the maximum travel of the motor when using the chair’s
control buttons)
• Motor speed (duty cycle)
• Motor polarity (reverses the motor)
• Button configurations (reverses or re-assigns buttons to different functions)
• Other functions
INSTALLATION