TABLE 4, HEAD LOSS at FLOW RATES/MINUTE and TEMPERATURE RISE SHOWN
INPUT
F°
18F°
20F°
HEAD LOSS
Boiler
MODEL
BTUH
KW
C°
10C°
11.1C°
Feet
M e t r e s
Inlet & Outlet
LB/LW-500
500,000
GPM
50
45
10
2” NPT
Natural
146
LPM
189
172
3.0
LB/LW-500
450,000
GPM
45
41
8.4
2” NPT
Propane
132
LPM
170
155
2.6
LB/LW-750
750,000
GPM
75
68
10.1
2” NPT
Natural
220
LPM
284
258
3.1
LB/LW-750
675,000
GPM
67
61
8.7
2” NPT
Propane
198
LPM
255
232
2.7
LB/LW-1000
1,000,000
GPM
100
91
8.9
2” NPT
Natural
293
LPM
378
344
2.7
LB/LW-1000
860,000
GPM
86
78
6.7
2” NPT
Propane
252
LPM
325
296
2.0
The ideal flow rate through the Legend models is considered to be the flow rate that results in
a 20 F° temperature rise across the unit. Table 4, shows head loss through units at
flow rate resulting in 20 F° rise. For head loss at other flow rates see sheet E202.2 in
A.O. Smith Architect’s & Engineer’s Manual.
ROUGH-IN DIMENSIONS (Continued)
TABLE 3, RECOVERY CAPACITIES
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
GAS
INPUT
F°
18F°
20F°
30F°
36F°
40F°
50F°
54F°
60F°
70F°
72F°
MODEL
TYPE
BTUH
KW
C°
10C°
11C°
17C°
20C°
22C°
28C°
30C°
33C°
39C°
40C°
LB/LW-500
Natural
500,000
GPH
3030
2727
1818
1515
1364
1091
1010
909
779
758
146
LPH
11471
10324
6882
5735
5162
4129
3824
3441
2950
2868
LB/LW-500
Propane
450,000
GPH
2727
2455
1636
1364
1227
982
909
818
701
682
132
LPH
10324
9291
6194
5162
4646
3716
3441
3097
2655
2581
LB/LW-750
Natural
750,000
GPH
4545
4091
2727
2273
2045
1636
1515
1364
1169
1136
220
LPH
17206
15485
10324
8603
7743
6194
5735
5162
4424
4301
LB/LW-750
Propane
675,000
GPH
4091
3682
2455
2045
1841
1473
1364
1227
1052
1023
198
LPH
15485
13937
9291
7743
6968
5575
5162
4646
3982
3871
LB/LW-1000
Natural
1,000,000
GPH
6061
5455
3636
3030
2727
2182
2020
1818
1558
1515
293
LPH
22941
20647
13765
11471
10324
8259
7647
6882
5899
5735
LB/LW-1000
Propane
860,000
GPH
5212
4691
3127
2606
2345
1876
1737
1564
1340
1303
252
LPH
19729
17757
11838
9865
8878
7103
6576
5919
5073
4932
U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
GAS
INPUT
F°
80F°
90F°
100F°
108F°
110F°
120F°
126F°
130F°
140F°
MODEL
TYPE
BTUH
KW
C°
44C°
50C°
56C°
60C°
61C°
67C°
70C°
72C°
78C°
LB/LW-500
Natural
500,000
GPH
682
606
545
505
496
455
433
420
390
146
LPH
2581
2294
2065
1912
1877
1721
1639
1588
1475
LB/LW-500
Propane
450,000
GPH
614
545
491
455
446
409
390
378
351
132
LPH
2323
2065
1858
1721
1689
1549
1475
1429
1327
LB/LW-750
Natural
750,000
GPH
1023
909
818
758
744
682
649
629
584
220
LPH
3871
3441
3097
2868
2816
2581
2458
2382
2212
LB/LW-750
Propane
675,000
GPH
920
818
736
682
669
614
584
566
526
198
LPH
3484
3097
2787
2581
2534
2323
2212
2144
1991
LB/LW-1000
Natural
1,000,000
GPH
1364
1212
1091
1010
992
909
866
839
779
293
LPH
5162
4588
4129
3824
3754
3441
3277
3176
2950
LB/LW-1000
Propane
860,000
GPH
1173
1042
938
869
853
782
745
722
670
252
LPH
4439
3946
3551
3288
3228
2959
2818
2732
2537