9
9.3.4 Wake Up Command
A) Press the study key three times
for the
Door/Window sensor
to
send
a
Wake Up Notification to
the
Gateway. Please make sure the Door/Window Sensor is added to the Z-wave network.
B)
How to use Wake Up Interval Set Command to set the Door/Window Sensor to automatic Wake Up.
1.
When the configured value is set 0~59 then the configuration is not available and the Wake Up
time cannot be changed.
2.
If the configured value is 60~119 then the Wake Up Interval time is 60 seconds.
3.
If the configured value is 120~179 then the Wake Up Interval time is 120 seconds.
Note: You can set additional configured values for longer Wake Up Interval times.
C) Wake Up Interval Capabilities Report CC
•
Minimum Wake Up Interval Seconds = 60 seconds
•
Maximum Wake Up Interval Seconds = 2678400 seconds=31 days
•
Default Wake Up Interval Seconds = 600 seconds
•
Wake Up Interval Step Seconds = 60 seconds
9.3.5 Battery Command
A) If the Controller or Gateway sends the Battery Get command to
the
Door/Window Sensor then
Door/Window Sensor will report the Battery Power Level to the Controller or Gateway.
•
If the Battery Voltage >3.0V the Battery Power Level is 100%.
•
If the Battery Voltage<2.3V the Battery Power Level is 0%.
B) If the Battery has a low voltage
of 1
0%
,
or less, the Configuration 0x0A setting threshold values
for the
Door/Window Sensor
will
report Battery Report 0xFF to Association Group 1.
9.3.6 Notification Commands
A) Notification Supported Report : Access Control (0x06)
、
Home Security (0x07)
B) Event Supported Report Command
Notification Type
Notification Event
Access Control (0x06)
Window/Door is open (0x16), Window/Door is closed (0x17)
Home Security
(
0x07
)
Tampering, Product covering removed (0x03), Previous Events cleared
(0x00)
9.3.7 Manufacturer Specific Report Commands
Parameter
Value
Manufacturer ID 1
0x03
Manufacturer ID 2
0x00
Product Type ID 1
0x00
Product Type ID 2
0x02
Product ID 1
0x00
Product ID 2
0x08
Содержание 7A-SS-VE-H0