8
9.3
Command Explain
9.3.1 Z-Wave Plus Info Command Report
Parameter
Value
Z-Wave
Plus
Version
V1
Role Type
6(ZWAVEPLUS_INFO_REPORT_ROLE_TYPE_SLAVE_SLEEPING_REPORTING)
Node Type
0 (ZWAVEPLUS_INFO_REPORT_NODE_TYPE_ZWAVEPLUS_NODE)
Installer Icon Type
0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL)
User Icon Type
0x0C06 (ICON_TYPE_SPECIFIC_SENSOR_NOTIFICATION_ACCESS_CONTROL)
9.3.2 Association Command
Door/Window Sensor supports only one association group.
Grouping Identifier
Max Nodes
Transmit Content
Group 1
0x05
1. Notification Report.
Sensor will send Notification Report when the
sensor body and magnet removed or
combined.
2. Battery Report.
Sensor will send Battery Report when the
battery level is low and the battery report’s
value is 0xFF.
9.3.3 Association Group Info Command
A) Association Group Name Command Report
Team No.
Value
1 St
The ASSIC of Lifeline: 4C 69 66 65 6C 69 6E 65
B) Association Group Info Command Report
Parameter
Team No.
Value
Profile
1 St
General: Lifeline, Profile MSB=0x00,Profile LSB=0x01
C) Association Group Command List Command Report
Team No.
Command List Support
1 St
COMMAND_CLASS_NOTIFICATION(0x71)
NOTIFICATION_REPORT(0x05)
COMMAND_CLASS_BATTERY(0x80)
BATTERY_REPORT(0x03)
COMMAND_CLASS_DEVICE_RESET_LOCA
LLY(0x5A)
DEVICE_RESET_LOCALLY_NOTIFICATION
(0x01)
Содержание 7A-SS-VE-H0
Страница 11: ... ...