When installing and using this electrical equipment, basic safety precautions must
always be followed, including the following:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Refer problems to qualified personnel.  Do not attempt to dismantle or repair.  No user serviceable parts.

Warranty void if tampered with.

3. WARNING - to reduce the risk of injury, do not permit children to install or operate this product.
4. WARNING - Risk of electric shock.  Connect only to a 110VAC grounding type receptacle protected by a

ground fault circuit interrupter (GFCI).  Contact a qualified electrician for installation or if you cannot verify
that the receptacle to be used is protected by a GFCI.

5. WARNING - Do not bury cord.  Locate system and cord to minimize abuse from lawnmowers, trimmers and

other equipment.

6. WARNING - To reduce risk of shock, replace damaged cord immediately.
7. WARNING - To reduce the risk of electric shock, do not use with extension cords.   Connect only to a 

properly installed and located electrical outlet.

8. WARNING - Do not use spas, hot tubs or pools unless all suction grates are installed to prevent body and

hair entrapment.

9. DANGER - To reduce risk of drowning from hair and body entrapment, install suction fitting(s) with a

marked flow rate that equals or exceeds the flow rate on the equipment assembly.

10. Do not install LECTRANATOR unit within an outer enclosure or beneath the skirt of a hot tub or spa.
11. CAUTION - Maintain water chemistry in accordance with manufacter’s instructions.
12. All field-installed metal components such as rails, ladders, drains, or other similar hardware within 3m (10

feet) of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not
smaller than No. 8 AWG in the U.S.A. and No. 6 AWG in Canada.

13. Follow all aspects of the local and National Electric Code(s) when installing this product.
14.

For outdoor installation, mount the LECTRANATOR Control Panel to ensure the least amount of direct

exposure to rain, direct sunlight or any corrosive environment.

15. Install at least 5 feet from the inside wall of the pool or spa.
16. A green ground wire is fastened to the inside of the Control Panel.  To reduce the risk of electrical shock,

connect this ground wire to the grounding terminal of your electrical service or supply panel with a 
continuous green or green & yellow striped insulated copper wire, equivalent in size to the circuit 
conductor supplying this equipment, but no smaller than No. 12 AWG (3.3mm2).

17. A security screw is provided on the access cover to restrict access to the Control Panel after installation.

Remove screw from access cover prior to installation, insert and tighten screw when installation is 
complete.

18.   SAVE THESE INSTRUCTIONS.

CAUTION

Failure to follow these instructions can result in fire, explosion, electric shock or electrocution.  

Read through and follow these instructions carefully before beginning the installation or start up of the

Lectranator system.

IMPORTANT SAFETY INSTRUCTIONS

1

Содержание 20151

Страница 1: ...CT Can treat a maximum of 180 000 litres of swimming pool water Maximum output of hypochlorous acid equivalent to 0 54 kg of free available chlorine per day For swimming pools a minimum of 1 ppm of free available chlorine must be maintained For spas a minimum of 3 ppm of free available chlorine must be maintained IMPORTANT READ THE LABEL AND OPERATING MANUAL BEFORE USING CL Marketing Inc 2770 24 A...

Страница 2: ...494 FAX 1 403 291 1023 Visit Us On The Internet http www tabex com Manufactured for CL Marketing Inc 2770 24 Avenue NE Calgary Alberta T1Y 6V7 Installer Date Installed Model Number Control Panel Serial Number Cell Serial Number Pool Gallons Record The Following Information ...

Страница 3: ... b Control panel Cell Installation 10 3 a Hi Voltage Wiring 11 3 b General Information 12 4 a Control Panel Indicators 13 4 b Start Up Sequence 14 5 a Trouble Shooting Model 360 840 15 16 Section 1 Water Pretest Preparation Section 2 Plumbing Requirements Section 3 Control Panel Mounting Wiring Section 4 Start Up Operation Section 5 Trouble Shooting M o d e l s 3 6 0 8 4 0 ...

Страница 4: ...t tub or spa 11 CAUTION Maintain water chemistry in accordance with manufacter s instructions 12 All field installed metal components such as rails ladders drains or other similar hardware within 3m 10 feet of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than No 8 AWG in the U S A and No 6 AWG in Canada 13 Follow all aspects of the local and ...

Страница 5: ...This feature is part of a start up cycle Thirty minutes after the Control Panel is energized a polarity reversal occurs which cleans the cell There after as long as the Control Panel is allowed to operate continuously without a power interruption an expected polarity reversal will take place approximately every 3 hours of main filter pump operation This setting is not selectable Since the OUTPUT C...

Страница 6: ...mpensate for this lower demand which will also protect your equipment from excessive levels of sanitizers 3 Cyanuric acid level maintained This chemical when added to pool water significantly inhibits chlorine depletion from exposure to sunlight Cyanuric acid levels must be maintained between 30 and 100 ppm to ensure that the chlorine being produced is protected from UV breakdown 4 Bather load As ...

Страница 7: ...he 8 demand variables for sanitizer 2 A Control Panel with a RC 15 cell operated at maximum output 5 0 amps at 3000 ppm salt residual will produce Sodium Hypochlorite equivalent to 0 545 kg of chlorine per day This amount of chlorine should satisfy higher demand applica tions depending on the 8 demand variables for sanitizer NOTE Residual salt levels must be maintained above 2800 ppm and below 320...

Страница 8: ...g it on Use only Sodium Bromide that is registered or scheduled under the Pest Control Products Act NOTE DO NOT allow large amounts of undissolved salt to remain on fresh cementitous pool spa interior surfaces Brush vigorously to accelerate salt dissolving especially in cold water conditions or in pools with inoperative or no main drains Stains From Salt CAUTION Generic bulk salts have anti caking...

Страница 9: ...deposits still remain repeat procedure using a fresh acid solution 4 Re installation of the cell s a Re install the cell s and tighten unions hand tight only b Before fitting the DC plug back onto the cell make sure the DC plug and cell posts are dry Push DC plug securely onto cell to prevent water damage c Always double check your connections to ensure that all DC plugs are connected to their des...

Страница 10: ...00 20000 30000 NOTE ABOVE CHART BASED ON 1 POUND OF SALT ADDED TO 1 MILLION POUNDS OF WATER APPROXIMATELY 120 000 GALLONS WHICH EQUALS 1 PPM OF SALT Pool Spa Volume in Liters 0 ppm 3 6 9 12 15 30 75 150 225 300 360 320 ppm 2 7 5 4 8 11 13 27 67 134 201 268 322 640 ppm 2 4 4 7 7 1 9 4 12 24 59 118 177 236 283 960 ppm 2 4 1 6 1 8 2 10 20 51 102 153 204 245 1280 ppm 1 7 3 4 5 2 6 9 8 6 17 43 86 129 1...

Страница 11: ...r to addition to pool water is advised KILOGRAMS OF CYANURIC ACID NEEDED FOR 75 PPM RESIDUAL Cyanuric Acid Needed for 75 PPM 8 Section 1 b Pool Spa Volume in US Gallons 0 ppm 0 12 0 31 0 47 0 62 0 94 1 6 3 1 6 2 9 4 12 5 18 7 12 ppm 0 1 0 26 0 39 0 52 0 79 1 3 2 6 5 2 7 9 10 5 15 7 25 ppm 0 08 0 21 0 31 0 42 0 62 1 2 1 4 2 6 2 8 3 12 5 37 ppm 0 06 0 16 0 24 0 32 0 47 0 79 1 6 3 2 4 7 6 3 9 5 50 pp...

Страница 12: ...nuric Acid stabilizer We recommend the Taylor Technologies Model K 2005 Test Kit 8 P V C Glue 9 P V C Cleaner Primer 10 Assorted P V C Fittings Pipe 11 Assorted Electrical Hookup Components 12 Teflon tape or pipe joint compound SUPPLIED BY LECTRANATOR 1 Residential Installation Operation Manual 2 Limited Warranty with Warranty Card Must Return 3 LECTRANATOR Control Panel 4 Chlorine Bromine Product...

Страница 13: ...oles with the permanent marker Using a 25 62 cm drill bit drill to a depth of 1 2 5 cm and install the supplied anchors The Control Panel is now ready to receive the 4 mounting screws to secure the installation DO NOT SHOOT OR PERMANENTLY ATTACH THE CONTROL PANEL TO THE WALL This will void warranty damage the Control Panel and make it virtually impossible to service without damaging the cover NOTE...

Страница 14: ...ontrol Panel indicated by a GREEN CELL ON indicator which initiates the electrolytic process and allows sanitizer to be produced This process converts salt Sodium Chloride to 100 Pure Sodium Hypochlorite Liquid Chlorine which in turn sanitizes your pool This processed salt then reverts back to salt and the entire process is repeated 3 The FLOW DETECTOR ensures adequate flow is present to produce s...

Страница 15: ...Control Panel Models 12 Section 3 b LECTRANATOR MODEL 840 LECTRANATOR MODEL 360 FLOW DETECTOR CORD FLOW DETECTOR FLOW DETECTOR TEE DC CELL CORD CELL UNIONS LECTRANATOR CONTROL PANEL 360 840 RC 15 RC 7 ...

Страница 16: ... d DC plug is not pushed tightly onto cell terminals e Failing cell or f Blown fuse D FLOW DETECTOR Normally this indicator will display dark This indicator will display RED whenever insufficient flow is present Typically the flow rate drops below 20 US Gallons min 75Liters Min Further if this indicator is displaying RED the GREEN CELL ON indicator will display dark If a RED indicator persists ple...

Страница 17: ...This is normal After sufficient flow is detected the RED FLOW DETECTOR indicator should display dark and approximately 5 10 sec onds later a GREEN CELL ON indicator should display If this sequence does not occur or any RED indicators display please refer to the Trouble Shooting Guide for further assistance NOTE Be sure to monitor the chlorine bromine level for the next few days and properly adjust...

Страница 18: ... plug and cell terminals burned A The cell cord plug is not securely pushed onto A Ensure that the cell cord plug is pressed completely onto the cell terminals the cell terminals allowing moisture to seep into the plug Check the cell terminals and clean with a dry cloth to remove all dirt and corrosion B The cell terminals leak B Shut off the main filter pump and patch the cell terminal s with epo...

Страница 19: ...ck with either a 504 or 957 cell tester Replace the cell if needed Refer to 4 of this section G Very cold pool water G Lower the output control dial setting even to the OFF position and add a non chlorine shock to the pool until the wtaer temperature increases above 14 C 60 F 9 Red FLOW DETECTOR light A Water exiting the filter is being diverted away from the inlet A Increase the flow rate above 1...

Страница 20: ...he risk to persons or property that arises from any such use of this product For swimming pools a minimum of 1 ppm of free available chlorine or bromine must be maintained For spas a minimum of 3 ppm of free available chlorine or bromine must be maintained Controls Bacteria and Algae in Swimming Pool Waters Maximum output of hypochlorous acid equivalent to 0 54 kg of free available chlorine per da...

Страница 21: ...RATION NUMBER 23160 PEST CONTROL PRODUCTS ACT This cell must only be used on these models of chlorine generating device Read the Label and the Installation and Operation Manual before using C L Marketing Inc 2770 24 Ave N E Calgary Alberta T1Y 6V7 PCP Cell Label 23160 RC7 S RT360 ENGLISH Final June 2005 ...

Страница 22: ...formation This service and this information do not replace the official hard copy label The PMRA does not provide any guarantee or assurance that the information obtained through this service is accurate current or correct and is therefore not liable for any loss resulting directly or indirectly from reliance upon this service ...

Отзывы: