Control Panel
Using the supplied anchors and screws,
the Control Panel should be mounted on a flat, sturdy, vertical surface away from direct
exposure to sunlight. The Control Panel is equipped with a 3.65m DC cell cord and flow detector cord. For ease of installation, please
ensure that both cords connect to the cell and flow detector while still providing slack in each cord for future service. Using a torpedo
level and permanent marker, hold and level the Control Panel on the surface to be mounted and dot each of the (4) mounting holes
with the permanent marker. Using a .25” (.62 cm) drill bit, drill to a depth of 1” (2.5 cm) and install the supplied anchors. The Control
Panel is now ready to receive the (4) mounting screws to secure the installation.
DO NOT SHOOT OR PERMANENTLY ATTACH
THE CONTROL PANEL TO THE WALL! This will void warranty, damage the Control Panel and make it virtually impossible to
service without damaging the cover. NOTE: Install at least 5 ft. (1.53m) from the inside wall off the pool or spa.
Control Panel & Cell Installation
10
Section 2 b
NOTE: The cell is a bi-directional flow device. When installing, do not glue or silicone the threads of the unions into the
body of the cell. This will void the warranty. Teflon tape or pipe joint compound is suggested.