background image

1

TREATMENT TANK

CONTROL INDICATOR PANEL

SALT FEED TANK

EC

Installation and Maintenance Instructions

THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED

DURING BOTH INSTALLATION AND OPERATION

WARNING:

Raritan Engineering Company, Inc. recommends that a qualified person or electrician install
this product. Equipment damage, injury to personnel or death could result from improper
installation. Raritan Engineering Company, Inc. accepts no responsibility or liability for
damage to equipment, or injury or death to personnel that may result from improper installation
or operation of this product.

WARNING:

HAZARD OF SHOCK AND FIRE - Always use recommended fuse/circuit breaker and wire
size.

WARNING:

HAZARD OF FLOODING - Always shut off seacocks before leaving boat unattended.
Double clamp all hose fittings below the waterline, check hose clamps frequently for integrity.

WARNING:

The Lectra/San EC operates on an Electrochemical  principle.  Introduction of any substance other
than salt water, human waste or toilet tissue may cause heat build up and extensive damage.  If any
other substance is introduced by accident, the Lectra/San EC must not be turned on until entire
system is flushed out with water.

INTRODUCTION

The Lectra/San EC is a U.S. Coast Guard Certified
Type I Marine Sanitation Device for uninspected
vessels less than 65 feet in length.  Lectra/San EC
accommodates most marine toilets.  It can be used
with one or two toilets (see page 10).  It is designed
and approved to treat waste for overboard discharge
in areas that are not declared a No-Discharge zone by
the U.S. Environmental Protection Agency.  The
total system is made up of three basic parts:

The Control Indicator Panel - Begins the treatment
cycle and can also be connected to flush an electric
toilet at the same time (single toilet application).

Dimensions:  4 1/2"H x 2 3/4"W x 1"D

The Treatment Tank - Consists of two chambers
and an electrode pack that temporarily converts

salt water into a powerful bactericide for the
duration of the treatment cycle
.  The top of the tank
contains the control module and its protective cover.

Dimensions:  16"W x 8 3/4"D x 13 1/2"H

Salt Feed Tank - Necessary to supply a saturated
salt solution when not operating in water of ocean
salinity.  Dimensions:  9"W x 9"D x 7"H

Additional parts included:   1 1/2" hose adapters
(2), 1 1/2" NPT Intake Plug,  90

°

 1 1/2" slip PVC

fitting, ribbon cable, salt tank attachments, Owners
manual, warranty information, template for Opera-
tion Instruction Wall Placard Indicator Panel and
U.S.C.G. Type I Equipped label.

NOTE:  To comply with U.S.C.G. Regulations, the
instruction wall placard should be placed near the
control indicator panel and the "U.S.C.G. Type I
Equipped" label MUST be in a visible location.

OPERATION

Press yellow button (Push to Flush) to activate
Lectra/San EC system.

NOTE:  Toilet must not exceed 1.5 gallons of
waste water during any total flush cycle.

1.  If your toilet is electrically connected with the

Lectra/San  EC (see Figs. 9 and 9A),  it will  flush
automatically.  You may  flush  the  toilet  as
necessary  at  10  second intervals  within  the  first
40  seconds  (duration  of the FLUSH cycle).

Содержание EC

Страница 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Страница 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Страница 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Страница 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Страница 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Страница 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Страница 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Страница 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Страница 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Страница 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Страница 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Страница 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...

Отзывы: