background image

8

Item Part No.

Description

13

14

2

15

22

1

3

2

20

21

6

10

16

11

9

7

8

10

11

17

8

18

7

19

14

21

4

4

5

5

12

2

EXPLODED  PARTS  VIEW  OF

COMPLETE   TREATMENT  UNIT

1

32-102**

Mixer Motor 2 1/2'' Dia. 12 VDC

1

33-102**

Mixer Motor 2 1/2'' Dia. 24 VDC

1

34-102**

Mixer Motoer 2 1/2" Dia. 32 VDC

2

31-121

Hose Fitting

3

31-120

Discharge Elbow 90

4

M30

Electrode Lug Nut, 1/4''-20 Brass (4)

5

M31

Electrode Flat Washer, 1/4'', Brass (4)

6

31-113-1

Cover Hold Down Bolt, 10-32x3/4'' (16)

7

31-103

Motor Shaft Bushing (2)

8

31-106

Motor Hold Down Bolt,10-32x7/8'',S/S(6)
(Hold down bolts must be completely
covered with silicone caulk before final
reassembly to prevent leaking.)

9

31-109

Mixer Impeller

10

31-110-1

Impeller Bolt, 12-24x5/8'', S/S (2)

11

31-110-2

Impeller Lock Washer, #12, S/S (2)

12

31-114

Cover Hold Down Nut, 10-32 (18)

13

31-115

Treatment Tank

14

31-122

Intake Plug

15

32-5000

Electrode Pack 12 VDC

15

33-5000

Electrode Pack 24 VDC

15

34-5000

Electrode Pack 32 VDC

16

31-112

Cover Gasket

17

31-108

Macerator Set Screw, 8-32x3/16'', S/S

18

31-107

Macerator Impeller

19

31-101W

Treatment Cover (Inc. items 7, 20 and
21)

20

31-104

Crossover Plug

21

31-102

Motor Shaft Seal (2)

22

32-101**

Macerator Motor 3'' Dia. 12 VDC

22

33-101**

Macerator Motor 3'' Dia. 24 VDC

22

34-101**

Macerator Motor 3'' Dia. 32 VDC

31-3001

Salt tank assembly (not shown)

32-4000*

12 V DC Complete Treatment Unit
(Items 1-22)

33-4000*

24 V DC Complete Treatment Unit
(Items 1-22)

34-4000*

32 V DC Complete Treatment Unit
(Items 1-22)

* Less Control Box Assembly
**NOTE:  When replacing existing or new motor(s), apply
silicone caulk over motor - hold down bolt heads.  Dispense
enough sealant to cover an area three times greater than the
bolt heads to avoid leaking through bolt holes.

Содержание EC

Страница 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Страница 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Страница 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Страница 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Страница 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Страница 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Страница 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Страница 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Страница 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Страница 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Страница 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Страница 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...

Отзывы: