7.   Reinstall all three fuses in proper sequence,  per

Fig. #10 and specifications table.

Salt Feed Tank:

1. Thoroughly rinse and wipe out tank.

2. Check to make sure the small vent hole in tank

cap is not blocked.

3. Rinse out connection hose with fresh water.

4. Clean T/Check Valve assembly.

STORAGE

Short Term Storage

NOTE: Failure to perform the following may
result in an odor problem and contribute to min-
eral buildup in the system.

If the boat's toilets are not going to be used for up to
one week,  activate the treatment unit and flush the
toilet(s) twice for the complete flush cycle before
leaving the boat.

Long Term Storage

If the boat's toilets are not going to be used for over
a week, follow short term storage instructions and
also purge the toilet hoses and Lectra/San EC with
fresh water.
See Recommissioning and Start up.

WINTERIZATION

WARNING: DO NOT USE ANTIFREEZE IN
LECTRA/SAN EC.

1. Run Treatment Cycle five times, flushing the

toilet for the entire duration of the 40 second
flush cycle.

2. Close seacocks.

3. Disconnect and drain hoses.

4. Using a pump, remove water from the Treatment

Unit (through crossover cap).

5. The electrode pack should be inspected and

cleaned.  Remove the Treatment Unit Cover and
pull out the electrode pack.  Rinse with fresh
water and clean with a stiff non-wire brush.
Empty any remaining water from the tank.

RECOMMISSIONING & START UP

1. Reconnect hoses and open seacocks.

2. Remove the three fuses from the Control Module

(located on the top of the Treatment Tank).  Mark

Fig. #4 - Lectra/San EC with vented loop (below waterline)

Below Waterline Installation Requires Vented Loop Between
Lectra/San Treatment Unit and Thru-Hull Fitting

Fig. #3 - Lectra/San EC with holding tank (above waterline)

Lectra/San EC

Lectra/San EC

Raw Water Strainer

TWK

Intake

Thru-Hull

and Seacock

Intake

Thru-Hull

and Seacock

Discharge

Thru-Hull

and Seacock

Discharge

Thru-Hull

and Seacock

Y Valve

PHII Marine

Toilet

PHII Marine Toilet

TWK

Raw Water

Strainer

Vented

Loop

Vented

Loop

Deck Pumpout

Vented

Loop

Vent Outside

Hull or Deck

Vent Outside

Hull or Deck

Fig. #2 - Lectra/San EC with Vented loop (above waterline)

each fuse for replacement purposes.  This will
allow operation of an electric toilet without acti-
vating the Lectra/San EC.

3. Flush the toilet four times, allowing approxi-

mately two gallons of salt water to enter the
Treatment Tank.

4. Reinstall the three fuses in proper sequence,

per Fig. #10.

INSTALLATION

Use Figures #2 through #4 which show some instal-
lation options.  (Drawing are not to scale.)

WARNING:  Below waterline installations must
include a vented loop.  The top of the loop must be

Содержание EC

Страница 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Страница 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Страница 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Страница 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Страница 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Страница 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Страница 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Страница 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Страница 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Страница 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Страница 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Страница 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...

Отзывы: