![Leadshine MX3660 Скачать руководство пользователя страница 24](http://html.mh-extra.com/html/leadshine/mx3660/mx3660_hardware-installation-manual_1864857024.webp)
Hardware
installation manual of the multi-axis drive MX3660
Leadshine Technology Co., Ltd
Leadshine America, Inc.
Page 24/25
11/F, Block A3, iPark,
No.1001 Xueyuan Blvd, Nanshan District, Shenzhen, China
25 Mauchly, Suite 318, Irvine, CA 92618, USA
Tel:
86-755-26409254
Fax: 86-755-26402718
Tel: 1-949-608-7270
Fax: 1-949-608-7298
Web
:
www.leadshine.com
Email:
Web:
www.leadshine.com
Email:
Appendix F: Stepper Drive Module Replacement
In the case that one of the three stepper drive modules of the MX3660 does not work (
the green LED light is not on
when the MX3660 is powered on
) you can replace it with a Leadshine SDM660 stepper drive module. Contact us for
getting a new SDM660.
Appendix G: Warranty Information
The MX3660 3-axis stepper drive comes with 12-month limited warranty under proper use. Contact your MX3660
supplier first for warranty service. If your MX3660 was bought through Leadshine or one of its subsidiaries, contact
us directly.
Appendix H: Trouble Shooting
In the case that the MX3660 doesn’t operate properly, the first step is to identify whether the problem is electrical
or mechanical in nature. The next step is to isolate the system component that is causing the problem. As part of
this process you may have to disconnect the individual components that make up your system and verify that they
operate independently. It is important to document each step in the troubleshooting process. You may need this
documentation to refer back to at a later date, and these details will greatly assist our Technical Support staff in
determining the problem should you need assistance.
Many of the problems that affect motion control systems can be traced to electrical noise, controller software
errors, or mistakes in wiring.
The following table shows some commonly asked symptoms and possible solutions.
Symptoms
Possible Cause
Solution
A motor doesn’t
move
No power
Connect Power
Wrong signal and / or stepper
motor connection
Correct the DB25 connector and / or stepper motor
connection(s)
No E-Stop connection
Option 1: connect an E-Stop switch. Or,
Option 2: short “E-Stop +” and “E-Stop+” pins
The stepper drive modules is
under protection
Make sure the power supply voltage is not too high.
Also look into your mechanic systems and make sure
it does not cause over current protection.
Control signal voltage is too low
Increase step width.
Motor spins in wrong
direction
Wrong motor wiring
Reverse wires on one phase of the stepper motor
Loss of steps
Wrong step enabling setting in
your controller
By default, MX3660 step enabling is “Active High”.
Change your step enabling configuration of your
controller to “Active High” also.
Direction set up time is too
short
Increase the direction set up time in your controller
to at least two times of pulse width
Interference
Shield your signal cables and keep the MX3660 as far
as possible, from other electronic components