Figure 13
Connecting the step & direction signals of a controller to the MX3660
!
Caution
If step & direction signal voltage is lower than 5 VDC, you may need to increase step
width and direction setup time (> 5 uS) to move your motors, or avoid loss of step.
13.2.
Connecting the DB25 Fault Output Pin
The fault pin connection is optional.
The MX3660 3-axis stepper drive will send a “Fault” output signal of 5 VDC
back to the controller via Pin 15 (Appendix A) of the DB25 connector, in one of the following scenario:
Any of the 3 stepper drive module is in protection mode including over voltage and over current. Read
“Protection” detail in the MX3660 datasheet.
The connected external E-Stop switch in the digital input is pressed.
With the receiving of a fault received from the MX3660, a controller can be notified an abnormal event has
happened. It can then react, such as shutting down the whole control machine/device for machine damage.
13.3.
Connecting the DB 25 Charge Pump Pin
The charge pump pin connection is optional.
To implement the “charge pump” feature of the MX3660 3-axis
stepper drive, turn off the Pulse Switch (page 7) and keep sending 10 kHz signals to Pin 16 of the DB25 connector
while the controller works properly. In this scenario, the “PULSE LED” on the MX3660 will be turned on to
indicate that everything is fine. When no such signal received, the MX3660 will be disabled with the “PULSE
LED” light off, to prevent from any further action caused by controller malfunction for connected stepper motors
and external devices. Read “Enabling / Disabling Charge Pump” in page 7 for additional information.
Connecting the DB25 PWM Pin
The PWM pin connection is optional.
The MX3660 can take PWM signals from the controller, through Pin 14 of