10.
Enabling / Disabling Charge Pump
To make the MX3660 working properly, setting this switch to the right position is required.
The MX3660 is
featured with a feature called “Charge Pump”, a watchdog timer to enable/disable the MX3660. When the
charge pump feature is turned on, the MX3660’s activation will depend on the receiving of 10 kHz signals at pin
16 of the DB25 connector. When the “Charge Pump” feature is turned off, the MX3660 will be activated without
such verification.
By default, the charge pump feature is turned on, with the “Pulse Switch” (next to the DB25 connector) set to
the “Off” position (means “Charge Pump” on). To disable this feature and make the MX3660 to work with
control systems (e.g. PLC, motion controller, etc.) not designed to use the “Charge Pump” feature, set the
“Pulse Switch” to “ON” position (meaning “Charge Pump” off).
Figure 11 On/Off positions for “Pulse Switch” and “Smoother” Switches
!
Caution
The ON/OFF direction for the “Pulse Switch” is different from the ON/Off direction
of the DIP switch in a stepper drive module, which is used to configure the output
current and micro step by a stepper drive module. Refer to Figure 11.
11.
Setting the “Smoother” Switch
The firmware of each of the three stepper drive modules in the MX3660 adopts a feature called
“smoothing” to smooth input step signals.
When an input pulse emulated by the connected motion
controller or CNC control system are not in linear or equivalent width, called “noise pulse”, it will cause erratic
motion and additional motor/drive noise. Turning on the built-in digital smoother will trigger the input pulse
train smoothing and could potentially improve motion performance such as less jittering, higher torque, and
quicker response. Because of the complexity for different machines/devices, the “Smoother” feature may or
may not have obvious effect (but at least no hurt for the bottom line). Turning on this switch or off is totally
your choice.
The “Smoother” switch is located next to the DB25 connector. By default, the MX3660 smoother is set to off.
!
Caution
The ON/OFF direction for the “Smoother” switch is different from the ON/OFF
direction of the three DIP switches for the 3 stepper drive modules, which is used to
configure output current and micro step by a stepper drive module. Refer to Figure