39
User
Manual
for
ELD2
Servo
You
can
select
whether
or
not
to
activate
Err0d.0
(main
power
under
‐
voltage
protection)function
while
the
main
shutoff
continues
for
the
setup
of
Pr5.09(The
main
power
‐
OFF
detection
time).
Setup value Action of main power low voltage protection
0
When the main power is shut off during Servo-On,Err0d.0 will not be triggered and
the driver turns to Servo-OFF. The driver returns to Servo-On again after the main
power resumption.
1
When the main power is shut off during Servo-On, the driver will trip due to
Err0d.0
Caution:
Err0d.0(main power under-voltage protection) is trigged when setup of Pr5.09 is long and
P-N voltage of the main converter falls below the specified value before detecting the main power
shutoff , regardless of the Pr5.08 setup.
Pr5.09*
The main power-OFF detection time
Range
unit
default
Related
control mode
70-2000
1ms
70
P
S T
You can set up the time to detect the shutoff while the main power is kept shut off continuously. The
main power off detection is invalid when you set up this to 2000.
Pr5.13
Over-speed level setup
Range
unit
default
Related
control mode
0-20000
r/min
0
P
S T
If the motor speed exceeds this setup value, Err1A.0 [over-speed protect] occurs.
The over-speed level becomes 1.2 times of the motor max, speed by setting up this to 0.
Pr5.15*
I/F reading filter
Range
unit
default
Related
control mode
0-255
0.1ms
0
P
S T
I/O input digital filtering; higher setup will arise control delay.
Pr5.28*
LED initial status
Range
unit
default
Related
control mode
0-35
-
1
P
S T
You can select the type of data to be displayed on the front panel LED (7-segment) at the initial
status after power-on.
Setup
value
content
Setup
value
content
Setup
value
content
0
Positional command
deviation
10
I/O signal status
27
Voltage across PN [V]
1
Motor speed
11
Analog input value
28
Software version
2
Positional command
speed
12
Error factor and
reference of history
29
Driver serial number
3
Velocity control
command
16
Inertia ratio
30
Motor serial number
4 Torque
command
17
Factor of no-motor
running
31
Accumulated operation
time
5 Feedback
pulse
sum 23
Communication axis
address
33
Temperature
information
6 Command
pulse
sum 24
Encoder positional
deviation[encoder
unit]
36
Safety condition
monitor
9 Control
mode
Pr5.29*
Baud rate setup of RS232
communication
Range
unit
default
Related
control mode
0-6
-
5
P
S T
You can set up the communication speed of RS232.
Pr5.30*
Baud rate setup of RS485
Range
unit
default
Related
control mode