H2-506 Vector Easy Servo Drive User Manual Version 1.0
Leadshine Technology Co., Ltd
11/F, Block A3, iPark, No.1001 Xueyuan Blvd. Shenzhen, China
Tel: 1-949-608-7270 Fax: 1-949-608-7298
Web
:
www.leadshine.com
Email:
M
Display Data
Edit Parameter
Select Data
ENT
Display Data
Select Parameter
Display
parameter
Edit Parameter
Confirm
M
Cancel
ENT
ENT
Select Function
Hold on 3 seconds
Reset Parameter
Clear Error Record
ENT
ENT
Auxiliary
Function
Write to
EEPROM
Start Writing
Writing Completes
ENT
M
M
M
Operation Procedure of the on-board HMI
Display Data Mode
This mode is active initially at drive’s power-up. In this mode, users can check the monitoring data as shown in the
following table.
Display Code
Name
Description
“L “
Low order digits display.
“H “
High order digits display.
“d00uEP”
Position error which is the difference between command and feedback.
Press “
” to switch between low and high order digits display.
“d01SPF”
Actual feedback motor speed in RPM.
“d02SPr”
Reference motor speed in RPM.
“d03PLF”
Actual feedback position in pulses.
“d04PLr”
Reference position in pulses.