12
EN
USE OF THE APPLIANCE
USE OF THE APPLIANCE
Start your appliance
Plug in the power cable and wait a few seconds for the controller
to start up (the display will show a line of scores). After start-up,
it will display the actual internal temperature and humidity in the
cabinet. In this case, press the on/off button
(18)
to turn it ON.
Set controller 2 to the desired temperature if different from the
default value of 12ºC, see
"Controller setting"
.
Control panel, controller
1 - Internal temperature display 2 -
On/Off button
Press to start or stop the appliance
3 - Increase button
4 - Decrease button
15 - Humidifying in
progress 16 - Fan indicator
If the fan is running
17 - LED indicator
On if the light is on
18 - Adjusts the internal
temperature 19 - Adjusts the
internal humidity
20 - Charcoal filter knob 21 -
Resistor
Displayed if the resistor is heating
Setting the temperature
The default temperature setpoint is 12ºC. You can adjust the
temperature inside your cabinet within a range of 5 and 20°C. It
is not possible to set a temperature outside this range.
Press the temperature setting button
(18)
. The temperature
value and the setting warning
(12)
will start flashing where the
setpoint value is displayed.
Adjust the setpoint temperature to the desired value using the
control buttons
(3)
or
(4)
. Confirm your choice by pressing the
button
(18)
.
Controller A: After waiting 10 seconds, the normal display
returns. Press and hold the SET button
(12)
for more than 2
seconds. The setpoint value is displayed and the °C or °F LED
flashes. Change the setpoint value with the buttons
(16)
or
(17)
within 10 seconds. To store the new value of the setpoint
5 - Compressor indicator
Lights up if the compressor is running, flashes if the "short
cycle" delay is active.
6 - Defrost active.
7 - Temperature unit 8 -
Manual defrost
9 - Error/alarm indicator
Lights up if an alarm sounds.
10 - Internal relative humidity display
11 - Humidity unit
12 - Configuration indicator
Temperature/humidity.
13 - Resistance indicator
Lights
up if the resistor is active.
14 -
Dehumidification in progress
value, press the SET button again or wait for 10s.
Controller B: If the setpoint is not changed within 30 seconds
after pressing the setting button
(18)
, the controller returns to the
originally stored value and the warning light
(12)
goes out. If the
setpoint is changed but not confirmed, after 30 seconds the
controller will assume the new setpoint and return to the
temperature display mode.
Setting the temperature
(therefore for Controller B)
Note: the values read on the controller are the actual
temperature and humidity inside the unit, so it is necessary
to wait until the new internal conditions are effective.
This appliance is designed as an ageing and maturing
cabinet and can also be used as a service appliance. All you
need to do is set the internal temperature to suit your
needs, a white wine should generally be served between 6
and 10°C, reds between 15 and 18ºC.
You must consider that this appliance is an ageing cabinet,
so the temperature change inside is slow. The time required
to reach the new setpoints, depending on the internal load
and temperature conditions, can be significant.
Содержание LMV1380D
Страница 9: ...9 FR CONTRÔLEUR A 20 18 3 17 13 16 5 7 1 10 12 11 9 14 15 4 19 2 21 6 8 CONTRÔLEUR B 40mm min F 1 0 ...
Страница 20: ...Fabriqué en Europe Importé par SIDEME SA BP200 92306 Levallois Perret cedex ...
Страница 29: ...9 EN CONTROLLER A 20 18 3 17 13 16 5 7 1 10 12 1 1 9 14 15 4 19 2 21 6 8 CONTROLLER B 40mm min F 1 0 ...
Страница 30: ...10 EN 0 A 0 B 0 0 A 1 2 1 G1 l G G2 E A 1 1 Max 150 B 1 0 I C 1 0 D 1 0 E 1 0 0 0 At 0 0 0 B A 1 0 B 0 A 0 0 0 ...
Страница 39: ...Made in Europe Imported by SIDEME SA BP200 92306 Levallois Perret cedex ...
Страница 48: ...9 NL REGELAAR A 20 18 3 17 13 16 5 7 1 10 12 11 9 14 15 4 19 2 21 6 8 REGELAAR B 40 mm min F 1 0 ...
Страница 49: ...10 NL 0 A 0 B 0 0 A 1 2 1 G l G G2 E A 1 1 Max 150 B 1 0 I C 1 0 D 1 0 E 1 0 0 0 At 0 0 0 B A 1 0 B 0 A 0 0 0 ...
Страница 60: ...Vervaardigd in Europa Geïmporteerd door SIDEME SA BP200 92306 Levallois Perret cedex ...