 2.2  CONTROLS

 2.2.1  ADVANCED FUNCTION CONTROLS 

(a) “MEM” 

The "MEM" button is located to the left of the

upper area of the keyboard. It allows access to the
con figured zone memory preselections.

(b) “EVENT” 

The   "EVENTS"   button   is   located   in   second

position   from   the   left   side   in   the   upper   area   of   the
keyboard.  Allows  access  to  the   selection of   system
events. 

(c) “CANCEL” 

The "CANCEL" button is located in the middle

of the upper area of the keyboard. It allows canceling
those   operations   that   require   con firmation.   It   also
serves   as   an   access   key   to   the   con figuration
functions of the equipment. 

(d) “RECALL” 

The "RECALL" button is located in the second

position from the right side in the upper area of the
keyboard.   It   allows   to   repeat   the   last   voice
announcement   message   into   the   selected   zone
memories. 

(e) “ALL / CLEAR” 

The   "ALL   /   CLEAR"   button   is   located   to   the

right  of   the  upper   area  of  the   keyboard.  Allows  the
selection of all available zone memories. When one
or   more   zone   memories   are   selected,   by   pressing
this button it will unselect all.

 2.2.2  CALL FUNCTIONS CONTROLS

(f) ZONE MEMORY

They are located in the lower half of the microphone desk. They allow the selection of

zone   memories,   and   the   voice   message,   one   or   several   simultaneously.   When   a   memory   is
selected, the memory indicator will be activated.

(g) “TALK”

It is located at the bottom of the keyboard, occupying the central area. It allows to request

the channel to make the voice announcement call through the selected zone memories. It also
acts as con firmation "OK" of the operations that require it. 

LDA Audio Tech – 31 Severo Ochoa - 29590 MALAGA, Spain. Tel: +34 952028805

3

User's Manual: MPS 8Z

Picture 2: Controls

Содержание NEO MPS 8Z

Страница 1: ...User s Manual Model MPS 8Z...

Страница 2: ......

Страница 3: ...7 4 CONNECTION AND SETTING UP 7 4 1 POWER SUPPLY 7 4 1 1 POWER SUPPLY SELECTOR 7 4 2 CONNECTION TO THE SYSTEM ACSI BUS 8 4 2 1 BUS TERMINATOR 8 4 3 MPS 8K EXPANSION KEYBOARDS INSTALATION 9 4 3 1 KEYBO...

Страница 4: ...ulated by qualified personnel 8 Pay attention to the connection polarity when operating the equipment with a direct current DC power source The reversed polarity connection can cause damage to the equ...

Страница 5: ...nes per memory 64 zones 2 Up to 64 zone memories with addressing of 8 zones per memory 512 zones by means of expansion keypads 3 8 memories for system events 4 Recall from latest live PA message 5 Din...

Страница 6: ...the problem persists see chapter 6 4 for resolution Yellow color 2 1 2 STATUS INDICATORS OF THE CALL CHANNEL The status indicators per channel show at all times their status or operating condition d...

Страница 7: ...st voice announcement message into the selected zone memories e ALL CLEAR The ALL CLEAR button is located to the right of the upper area of the keyboard Allows the selection of all available zone memo...

Страница 8: ...VOICE ALARM SYSTEM ACSI LOOP The equipment has two connections for distributed elements in Public Address systems It consists of a line level audio input plus control signals for connecting up to 8 de...

Страница 9: ...iption Type Signals Activation Expansion port I O N A Table 4 Expansion port 3 OPERATION DESCRIPTION 3 1 TURNING ON Select the power supply origin as shown on 4 1 Connect the power supply cable into P...

Страница 10: ...ne 1 we can select Zone 1 and in the memory 2 the zone 2 The zones assigned to each zone memory can contain up to 8 zones of the system Thus one MPS 8Z can address up to 64 zones of the system and up...

Страница 11: ...l If the system has been able to launch the event the CW indicator will blink twice 4 CONNECTION AND SETTING UP 4 1 POWER SUPPLY The MPS 8Z is provided with an external power supply of 5V DC A female...

Страница 12: ...ng up of the LINK and EMG indicators The set bus adress will be indicated by lighting the indicator of the zone memory associated Push the memory selection button whose number corresponds with the des...

Страница 13: ...follow the next steps Disconnect MPS 8Z from the ACSI bus and from the power supply Place the connection adapter supplied with the expansion keyboard on the chosen side and connect both the paging sta...

Страница 14: ...Zones 57 64 ID 8 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 9 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 0 Zones 9 16 Selection not allowed by defa...

Страница 15: ...igital Sound Adjustment is a Digital Voice Processing that automatically adjust the gain of the voices of different users When this function is enabled the zone 4 light will remain on To confirm the n...

Страница 16: ...ipment will restart Configure the address accordingly see 4 2 If this procedure does not work disconnect the unit from the ACSI bus and contact LDA s Support Department Once the unit is removed if the...

Страница 17: ...s Support Department RMA and ask for a replacement You can keep using the equipment while the gooseneck is being replaced by using an external microphone and following the steps of chapter 4 4 3 If t...

Страница 18: ...Disconnect the first keyboard that is not switched on and connect the rest to the MPS 8Z If necessary re configure the address following chapter XX and the content of each zone through the System s Co...

Страница 19: ...ated ring for conceded word Buttons 3 buttons for special functions Memory Events and Cancel Re call button Selection deselection button of all zones 8 zone memory buttons 1 Talk button Functions Gong...

Страница 20: ...Ver 2...

Отзывы: