background image

 4.3.1  KEYBOARD ID

The keyboard ID selection roulette is only available in the

expansion   keyboards   attached   to   the   MPS-8Z.   This   selection
roulette is located at the base of the device in the central part. It
allows to select the location of the keyboard within the set of all
the attached keyboards. Each keyboard should have a different
ID. In a PA/VA System where the Zone Buttons have not been
con figured (with NEO Con figurator), the zone associated to each
button will be determined by the ID selected in the roulette. The
zone assigned to each button will be by default as follows:

ID 1: Zones 9-16

ID 2: Zones 17-24

ID 3: Zones 25-32

ID 4: Zones 33-40

ID 5: Zones 41-48

ID 6: Zones 49-56

ID 7: Zones 57-64

ID 8: Zones 9-16 Selection not allowed, by default it will
assigned ID 1.

ID 9: Zones 9-16 Selection not allowed, by default it will
assigned ID 1.

ID 0: Zones 9-16 Selection not allowed, by default it will
assigned ID 1.

 4.4  MPS 8Z CONFIGURATION

It   is   possible   to   con figure   MPS-8Z   Paging   Microphone   according   to   several   operation

parameters. To access the con figuration mode of the device, follow these steps:

Make sure the device does not have conceded word. The “CW” light should be off.

Keep pressed the button “CANCEL” and the button “EVENT” for at least 2 seconds.

When you are in the con figuration mode, the “FAULT” and “EMG” lights will be blinking.

Con figure the parameters as shown in chapter  4.4 .1 to  4.4 .6.

Press the button “TALK” to con firm, or “CANCEL” to cancel any change.

The device will restart with the new con figuration.

10

www.lda-audiotech.com

Picture 8: MPS-8K Expansion

Keyboard ID

Содержание NEO MPS 8Z

Страница 1: ...User s Manual Model MPS 8Z...

Страница 2: ......

Страница 3: ...7 4 CONNECTION AND SETTING UP 7 4 1 POWER SUPPLY 7 4 1 1 POWER SUPPLY SELECTOR 7 4 2 CONNECTION TO THE SYSTEM ACSI BUS 8 4 2 1 BUS TERMINATOR 8 4 3 MPS 8K EXPANSION KEYBOARDS INSTALATION 9 4 3 1 KEYBO...

Страница 4: ...ulated by qualified personnel 8 Pay attention to the connection polarity when operating the equipment with a direct current DC power source The reversed polarity connection can cause damage to the equ...

Страница 5: ...nes per memory 64 zones 2 Up to 64 zone memories with addressing of 8 zones per memory 512 zones by means of expansion keypads 3 8 memories for system events 4 Recall from latest live PA message 5 Din...

Страница 6: ...the problem persists see chapter 6 4 for resolution Yellow color 2 1 2 STATUS INDICATORS OF THE CALL CHANNEL The status indicators per channel show at all times their status or operating condition d...

Страница 7: ...st voice announcement message into the selected zone memories e ALL CLEAR The ALL CLEAR button is located to the right of the upper area of the keyboard Allows the selection of all available zone memo...

Страница 8: ...VOICE ALARM SYSTEM ACSI LOOP The equipment has two connections for distributed elements in Public Address systems It consists of a line level audio input plus control signals for connecting up to 8 de...

Страница 9: ...iption Type Signals Activation Expansion port I O N A Table 4 Expansion port 3 OPERATION DESCRIPTION 3 1 TURNING ON Select the power supply origin as shown on 4 1 Connect the power supply cable into P...

Страница 10: ...ne 1 we can select Zone 1 and in the memory 2 the zone 2 The zones assigned to each zone memory can contain up to 8 zones of the system Thus one MPS 8Z can address up to 64 zones of the system and up...

Страница 11: ...l If the system has been able to launch the event the CW indicator will blink twice 4 CONNECTION AND SETTING UP 4 1 POWER SUPPLY The MPS 8Z is provided with an external power supply of 5V DC A female...

Страница 12: ...ng up of the LINK and EMG indicators The set bus adress will be indicated by lighting the indicator of the zone memory associated Push the memory selection button whose number corresponds with the des...

Страница 13: ...follow the next steps Disconnect MPS 8Z from the ACSI bus and from the power supply Place the connection adapter supplied with the expansion keyboard on the chosen side and connect both the paging sta...

Страница 14: ...Zones 57 64 ID 8 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 9 Zones 9 16 Selection not allowed by default it will assigned ID 1 ID 0 Zones 9 16 Selection not allowed by defa...

Страница 15: ...igital Sound Adjustment is a Digital Voice Processing that automatically adjust the gain of the voices of different users When this function is enabled the zone 4 light will remain on To confirm the n...

Страница 16: ...ipment will restart Configure the address accordingly see 4 2 If this procedure does not work disconnect the unit from the ACSI bus and contact LDA s Support Department Once the unit is removed if the...

Страница 17: ...s Support Department RMA and ask for a replacement You can keep using the equipment while the gooseneck is being replaced by using an external microphone and following the steps of chapter 4 4 3 If t...

Страница 18: ...Disconnect the first keyboard that is not switched on and connect the rest to the MPS 8Z If necessary re configure the address following chapter XX and the content of each zone through the System s Co...

Страница 19: ...ated ring for conceded word Buttons 3 buttons for special functions Memory Events and Cancel Re call button Selection deselection button of all zones 8 zone memory buttons 1 Talk button Functions Gong...

Страница 20: ...Ver 2...

Отзывы: