75.5318.00 20080111
Page 5 of 9
ELECTRICAL
INSTALLATION-
CABLING &
CONNECTIONS
(Cont’d)
MECHANICAL
ADJUSTMENTS –
POSITIONING AND
ANGLING THE
MODULES
2.
Once all wiring has been completed, the end caps and lens may be installed. At the DMSS end of the cable (picture
23), leave enough slack to allow a relaxed connection at the terminal block. Locate the DMSS end cap that goes
towards the hinged end of the door. Remove the tab at the bottom of the cap (picture 21) to allow insertion of the plastic
sheath. Insert the plastic sheath (picture 22) and install the end cap. The DMSS lens may then be installed to fit tight
against the end cap and plastic sheath to hold it in place, as shown in picture 24. Leave the end cap off at the opposite
end until all mechanical adjustments have been completed.
* REFER TO THE BACK OF THIS GUIDE FOR WIRING SCHEMATICS.
1.
The positioning of the modules within the aluminum extrusion will be as shown below. The modules will always be
positioned so that the transmitter (TX) is at the leading edge of the door. Modules may be flipped around to accommodate
handing of doors.
Approach Side
Safety Side
Hinge Side
Leading Edge
Side
Slave module
Master module
Door Cord
(must be placed on interior of door)
TX
RX
TX
RX
Master Module
Slave Module
O
U
T
P
U
T
I
N
P
U
T
Ribbon Cable
Ribbon Cable
21
22
23
24