background image

 

75.5318.00   20080111 

 

Page 1 of 9 

DESCRIPTION 

TECHNICAL 
SPECIFICATIONS 

INSTALLATION 
TIPS 

‰

 

The sensor must be 
firmly fastened to 
prevent v bration. 

COMPONENT ID 

 

 

 

The Door Mounted Safety Sensor (DMSS) (8310-804) detector is a door-mounted presence detection system that is used on 
automatic pedestrian swing doors.  Unlike other door-mounted sensing devices, the sensors unique electronic architecture allows 
the detection modules to be mounted near the top of the door, out of harm's way.  A rotating cam is used for the range adjustment 
of the detection zone. Width patterns may be altered by adding slave modules to the master module.  These slave modules are 
simply added by inserting them into the aluminum extrusion, then connecting them with the attached flat ribbon cable to the next 
module without interrupting other modules in the same extrusion.  Once installed, the detection zone (in addition to being 
adjustable for distance) can be angled independently from the other modules.  
 
Each DMSS module consists of two optics, a transmitter (TX) and a receiver (RX), and functions independently of the other 
modules.  The transmitter emits an extremely precise beam, which measures approximately 4" in diameter at a distance of 8'.  
The receiver, in turn, receives the infrared beam reflected off of the floor.  This transmission and reception forms a detection 
triangle, which is the basic premise of detection (called triangulation).  Should this angle be interrupted, detection will occur.  
Detection is NOT based upon the intensity of the beam, and in principle will not be affected by the color or background of the 
object that interrupts the angle. 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 

 
 
 
 

 

 
 
 
 
 
 

 

DESCRIPTION 

SPECIFICATION 

Power Supply 

12 to 24 VAC ± 10% / 12 to 24 VDC + 10%    

Current Consumption: 
 

Master: On = 60 mA max. / Master: Off = 30 mA max.             
Slave: On = 40 mA. Max. /  Slave: Off = 30 mA max.                   

Input Inhibit 

12 to 24 VAC ± 10%:  /  12 to 24 VDC + 10%  /  Inhibited when voltage is applied 

SMR Input Data 

12-18 VDC: Inhibited when voltage is applied 

Output Interface; relay 

Relay; max. contact rating is 1A @ 30v ( resistive) 

Detection Range 

0' to 8' 

Distance Adjustment 

2’ to 8’  /   Rotating cam with linear adjustment  

Max. Mounting Height 

8’ 

Detection Time 

< 50 ms 

Detection Signal Duration 

Infinite Presence Detection 

Output Hold Time 

Potentiometer Range: 0.1 to 4.5 seconds. 

LED Indications 

Master: Red LED = Detection  
             Green LED = Active Output 
Slave:   Red LED = Detection 

Operating Temperature Range 

-30° F to 140° F 

PCB Dimensions 

Master: 10.91" x 1.5" 
Slave: 8.75" x 1.5"  

Connection to Door Controller 

8 Position Screw Terminal on Master PCB 

Connection: Master to Slave 

Flat R bbon Cable With Connectors and Key Lock 

Max. Number of Slaves 

Standard = 9  /  With Monitoring = 8 max. 

Functions Selection 

Detection Mode - NO or NC 
Normal Mode or Background Analysis Mode 

‰

 

Sensor must be in a location 
that does not interfere with door 
hardware (finger guards, lock 
rods, etc.).

‰

 

The sensor must not 
have any unwanted 
objects likely to move or 
vibrate in its path. 

DOOR MOUNTED 
SAFETY SENSOR 

DMSS 

Quick Disconnect Cable 

(8310-847) 

Jamb Cap (2) 

8310-804   DOOR MOUNTED SAFETY SENSOR

USER’S GUIDE

Содержание 8310-804

Страница 1: ...ld this angle be interrupted detection will occur Detection is NOT based upon the intensity of the beam and in principle will not be affected by the color or background of the object that interrupts t...

Страница 2: ...sion as shown in Picture 2 above Do not use a screwdriver to pry the lens as cracking may occur 4 Picture 3 below shows the angle adjustment clip in its proper position within the extrusion PCB s are...

Страница 3: ...to the safety side as shown below Again be sure not to drill through any through bolts or braces within the door A cutaway view below Picture 13 shows wire passage through the door Picture 12 and 14 s...

Страница 4: ...0 may be completed Wiring will vary according to the application Available positions on the connector are shown below TERMINAL EXPLANATION OF WIRING CONNECTIONS 1 TST TEST DATA Used with SMR systems o...

Страница 5: ...he DMSS lens may then be installed to fit tight against the end cap and plastic sheath to hold it in place as shown in picture 24 Leave the end cap off at the opposite end until all mechanical adjustm...

Страница 6: ...is jumper set to Normal Mode Power the sensors up with 12 to 24 VAC 10 or 12 to 24 VDC 10 LED status should reflect what was configured for the relay output Use a white gray or black piece of cardboar...

Страница 7: ...complete solution For more information visit www lcn ingersollrand com Door Mounted Safety Sensor does not work at all No LED indications Faulty power supply Faulty connections Power supply must be 12...

Страница 8: ...75 5318 00 20080111 Page 8 of 9 APPENDIX WIRING DIAGRAMS...

Страница 9: ...75 5318 00 20080111 Page 9 of 9 APPENDIX WIRING DIAGRAMS Cont d...