75.5318.00   20080111 

 

Page 4 of 9 

ELECTRICAL 
INSTALLATION- 
CABLING & 
CONNECTIONS  

 

MECHANICAL 
INSTALLATION- 
PREPARING AND 
MOUNTING THE 
SENSOR  (Cont’d) 

 

 

9. 

Next, a wire passage hole will be required in the door header (Picture 15) and also in the jamb tube (Picture 16) at 
approximately the same height as the Door Mounted Safety Sensor.  The wire transfer hole in the jamb should be at 
the secure side of the door. Normally this would be the interior side.  Feed the wire through the jamb tube up to the 
header. Insure that enough wire is left out to reach the Door Mounted Safety Sensor terminal block. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 

10.  Once all cabling is in place, the plastic sheath must be installed over the wire coming out of the jamb tube. This must 

be done before making final connection to the terminal block. The sheath may have to be cut to fit the application. 
Once the wire is fed though, the plastic cap may be installed on the jamb, over the transfer hole.  

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 

1. 

With cabling in place, wiring at the terminal connector on the DMSS master module (picture 20) may be completed. 
Wiring will vary according to the application. Available positions on the connector are shown below: 

 
 
 
 
 
 
 

 

TERMINAL 

EXPLANATION OF WIRING CONNECTIONS 

1   TST 

TEST DATA - Used with SMR systems only.  

2   GND 

GROUND -  Negative terminal if Input inhibition is used. 

3   INH 

INPUT INHIBITION - All detection is ignored.  Infrared emission is stopped.  Inhibition occurs 

when 12 to 24 VAC ± 10% or 12 to 24 VDC + 10% is applied between terminal 3 and 
terminal 2. 

4   NO 

In the relay mode, depending on the position of JP2 this terminal will provide either a NO or 
NC contact. (JP2 factory default will result in NC on terminal 4) 

5   NC 

In the relay mode, depending on the position of JP2, this terminal will provide either a NO or 
NC contact. (JP2 factory default will result in NO on terminal 5) 

6   COM 

COMMON - Contact for relay.  

7   - 

NEG. POWER - This terminal is used for power input.  A voltage of 12 to 24 VAC ± 10% or  
12 to 24 VDC + 10%  must be supplied. 

8   + 

POS. POWER - This terminal is used for power input.  A voltage of 12 to 24 VAC ± 10% or 

12 to 24 VDC + 10%  must be supplied.   

NOTE:  Ensure there is enough slack in cabling to allow adequate movement of the cable throughout the range 
             of door travel. 

Plastic ribbed sheath 

J2

J1

J4

J3

P1

1

15 

16 

17 

18 

19 

20 

Содержание 8310-804

Страница 1: ...ld this angle be interrupted detection will occur Detection is NOT based upon the intensity of the beam and in principle will not be affected by the color or background of the object that interrupts t...

Страница 2: ...sion as shown in Picture 2 above Do not use a screwdriver to pry the lens as cracking may occur 4 Picture 3 below shows the angle adjustment clip in its proper position within the extrusion PCB s are...

Страница 3: ...to the safety side as shown below Again be sure not to drill through any through bolts or braces within the door A cutaway view below Picture 13 shows wire passage through the door Picture 12 and 14 s...

Страница 4: ...0 may be completed Wiring will vary according to the application Available positions on the connector are shown below TERMINAL EXPLANATION OF WIRING CONNECTIONS 1 TST TEST DATA Used with SMR systems o...

Страница 5: ...he DMSS lens may then be installed to fit tight against the end cap and plastic sheath to hold it in place as shown in picture 24 Leave the end cap off at the opposite end until all mechanical adjustm...

Страница 6: ...is jumper set to Normal Mode Power the sensors up with 12 to 24 VAC 10 or 12 to 24 VDC 10 LED status should reflect what was configured for the relay output Use a white gray or black piece of cardboar...

Страница 7: ...complete solution For more information visit www lcn ingersollrand com Door Mounted Safety Sensor does not work at all No LED indications Faulty power supply Faulty connections Power supply must be 12...

Страница 8: ...75 5318 00 20080111 Page 8 of 9 APPENDIX WIRING DIAGRAMS...

Страница 9: ...75 5318 00 20080111 Page 9 of 9 APPENDIX WIRING DIAGRAMS Cont d...

Отзывы: