MED HP Batteries 

 Installation & User Guide 

Installation & User Guide  

HP Batteries; Medium Size 

19 

BIC 1, 2, 3 LEDs 

The BIC 1, 2 and 3 LED lights relate to corresponding BIC voltmeter. A solid green BIC LED means that 

the correspond BIC port is charging; a green flashing LED means that port is discharging 

 

COMMS Port 

The  COMMS  (or  communications)  port  is  where  the  remote  monitoring  screen  is  connected  via  a 

RJ12 plug (like old telephone cables). The remote monitoring screen is discussed in the next section. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BIC 1, 2, 3 

Voltmeters 

Содержание LBS-12150-HP-REG

Страница 1: ...HP REG LBS 12200 HP BIC LBS 12225 HP REG LBS 12225 HP BIC LBS 12300 HP REG LBS 12300 HP BIC LBS 2475 HP REG LBS 2475 HP BIC LBS 24110 HP REG LBS 24110 HP BIC LBS 24150 HP REG LBS 24150 HP BIC LBS 367...

Страница 2: ...to water or salt spray 6 2 6 Do not short circuit the battery 6 2 7 Mounting orientation 6 4 0 Longevity Depth of Discharge 7 4 1 Discharge Curve 7 5 0 Installation 9 5 1 Securing the Battery 9 Mounti...

Страница 3: ...titive Tripping 18 Reset from Display Screen 18 Reset from Battery 18 START Button Hibernation Shutdown 18 SHUTDOWN Button 18 BIC 1 2 3 LEDs 19 COMMS Port 19 7 0 Remote Monitoring Screen 20 POWER Butt...

Страница 4: ...es Installation User Guide Installation User Guide HP Batteries Medium Size 3 1 0 Acronyms Abbreviations BIC Built In Controllers BMS Battery Management System HP High Power LBS Lithium Battery System...

Страница 5: ...current from a vehicle alternator start battery The BIC DCS model not covered in this user guide contains a further DC DC charger to regulate charging from a vehicle with a smart alternator In the co...

Страница 6: ...y enclosure You may be tempted to drill into the aluminium enclosure to secure mounting brackets Doing so may inadvertently penetrate one of the cells which could cause thermal runaway and vapour emis...

Страница 7: ...battery Whilst the BMS will protect the internal cells from short circuit it is highly recommended to avoid short circuiting the battery Appropriately sized external fuses should be used where possibl...

Страница 8: ...will not allow the battery to remain at a maximum charge level Keeping your battery at a maximum is not as important as it is for lead acid batteries A battery lifespan is rated by the number of cycle...

Страница 9: ...User Guide HP Batteries Medium Size 8 Figure 4 1 Volt Curve Lead Acid vs Lithium 0 2 4 6 8 10 12 14 16 0 10 20 30 40 50 60 70 80 90 100 Battery Voltage V Depth of Discharge DoD Discharge Curve Lithiu...

Страница 10: ...ent a projectile hazard in the event of an accident Refer to the specific battery model datasheet for mounting bracket options As mentioned earlier in section 2 do not remove rivets or penetrate the e...

Страница 11: ...minal post This is the main connection point for all loads Wiring for these should be connected in the order described below Additional input options are available via Anderson plugs for the BIC and B...

Страница 12: ...motor controller We recommend not to use isolation switches or circuit breaker between the batteries and inverter motor controller as this can cause issues with inrush currents into capacitors if the...

Страница 13: ...trip an error if current exceeds 45A The uses for these additional inputs are summarised below Grey Directly connected to the main terminals to allow additional temporary loads and charging sources t...

Страница 14: ...blocking and allow charging again 5 4 Voltmeters Voltmeters are connected directly to the Anderson plugs they are next to for diagnostic purposes Therefore they show the voltage of whatever is plugge...

Страница 15: ...e the BMS is the heart and soul of a lithium battery The HP battery BMS is a highly reliable and functional solid state device which is primarily designed to keep the cells safe and the overall pack f...

Страница 16: ...ce is illustrated in Figure 6 3 and shows a close up of the Comms port Status LED Shutdown Button Start Button Power button and BIC 1 2 3 LED status light which are discussed below Figure 6 3 HP BMS U...

Страница 17: ...rature wait to recover 4 Battery too cold UTD Under Temperature Discharge Loads Disconnected Increase Reduce Temperature wait to recover 5 Battery too hot OTD Over Temperature Discharge 6 Short Circui...

Страница 18: ...voltage i e the Level SOC does not affect this Therefore the Level could be 0 well before the disconnection occurs this is intentional similar to the reserve fuel tank of a vehicle Conversely the Leve...

Страница 19: ...Reset from Display Screen You can press the Enter right hand button on the display screen to reset the battery This is the same button that cycles through the information screens on the Display when t...

Страница 20: ...ng BIC voltmeter A solid green BIC LED means that the correspond BIC port is charging a green flashing LED means that port is discharging COMMS Port The COMMS or communications port is where the remot...

Страница 21: ...tery can be powered on and off using the left hand power button on the display screen This mirrors the function of the blue POWER button on the top of the battery As soon as the battery is turned on t...

Страница 22: ...parallel within the 12V system this screen indicates the overall system level SOC state of charge One minute after being turned on this screen will automatically appear to show that the screen is che...

Страница 23: ...before connecting the remote screen This ensures that when the screen first powers on it finds all batteries connected to the network Below is a summary page that indicates the battery charge level t...

Страница 24: ...will indicate the Amps being supplied a positive number If you are not seeing all of the connected batteries i e the number on the summary page is less than the number of batteries in your system do t...

Страница 25: ...6 1 Prev W is previous warning code T how many times max temperature has been reached S shows if settings have been changed denotes battery number for a network of batteries BIC and REG models may be...

Страница 26: ...Low readings of 0 3 Amps can be taken as a zero value due to the response of the electronics to small changes in measurement For example if you had a solar panel connected to the black Anderson connec...

Страница 27: ...MED HP Batteries Installation User Guide Installation User Guide HP Batteries Medium Size 26 7 0 Specifications Figure 7 1 Battery Specifications...

Страница 28: ...Size 27 8 0 Contact Us Head Office Manufacturing Address Unit 16 20 22 Ellerslie Road Meadowbrook QLD 4131 Phone 1800 844 869 Office Hours 8am to 4pm Monday to Friday Email info lithiumbatterysystems...