GAS CONNECTIONS
fittings necessary to attach the hose
assembly to the grill are included.
BULK TANK LP:
Some residences and/or commercial
establishments use bulk propane cylinders
and are permanently plumbed with LP
connections. When this is the case, then a
4/11 regulator must be obtained and set for
the proper gas type (LP). 4/11 regulators
are convertible from NG to LP. To convert,
follow the instructions provided by the
regulator’s manufacturer.
WARNING
Do not change the regulator/ hose
assembly or use any other assembly other
than the one supplied with your LazyMan
grill.
Do not attempt to use a 5LP-A equipped
regulator/hose assembly with a standard
510 POL cylinder/valve assembly.
Do not store a spare LP gas cylinder under
or near this appliance
LP CYLINDER REQUIREMENTS:
The LP cylinder must be constructed and
marked in accordance with the U.S.
Department of Transportation (DOT) spec-
ifications for LP cylinders and be designed
for use with a Type 1 system only.
When exchanging your cylinder for a refill,
exchange only with a Type 1, 20 lb cylinder
with an overfill protection device.
Never use a cylinder with a damaged valve.
A dented or rusty LP cylinder may be
hazardous and should not be used. If in
doubt, have it checked by your LP supplier.
Always shut off the LP gas when finished
using the grill, both at the grill valves and
the LP cylinder valve.
Cylinders must always be stored outdoors in
a well ventilated area and out be of reach of
children. If your grill is stored indoors, the
LP cylinder must be removed and stored
outdoors.
LP CONNECTIONS:
Make sure the LP cylinder valve is fully
closed before connecting to the grill. It is
possible for the valve to be partially open
without releasing gas, but, as soon as the
regulator is connected, gas can leak from
the connection. Insert the regulator inlet
into the cylinder valve and turn the black
coupler clockwise until the coupler is hand
tight. Do not over-tighten this connection.
To disconnect the coupler, first make sure
the cylinder valve is turned completely off.
Turn the coupler counter-clockwise. The
inlet will then disengage.
Always leak test the connection after
refilling or exchanging LP gas cylinders. See
‘Leak Test Procedure’.
GAS LINE PURGING:
After refilling or replacing an LP gas
cylinder, it is always best to purge the
system of air before attempting to light the
grill.
Make sure all controls are in the “OFF”
position.
7