LS-CS-M-023
PCSS-F Additions Technical Manual
Page 4-29
Original Language Version:
1.02
Released:
03/12/2013
X34
X35
X36
X37
P34
FIO04
–
CN9
1
2
3
4
5
P35
6
P36
7
P37
8
24VDC
9
0VDC
10
X38
X39
X40
X41
Y08
FIO04
–
CN10
1
2
3
4
5
Y09
6
24VDC
7
0VDC
8
0VDC
9
Hand Button 1
–
Left
Hand Button 1
–
Right
Hand Button 2
–
Left
Hand Button 2
–
Right
Figure 4-27: Dual Operator Foot Control (CN9/10
-
FIO04 Connections)
The connections in this option allow dual operator station with foot pedal control on each as
shown in
for the FIO04 module. In this application both the normally open (NO)
and normally closed (NC) contacts from the foot pedal switches on each of the operator
stations are monitored. The NO contacts are monitored using standard inputs, while the NC
contacts are monitored using safety inputs as shown in
This option provides for dual operator stations with either the 1 Foot - 1 Foot operator mode on
one of the stations selected and
modified down switch control function on the other
or the 2
Foot - 2 Foot on both stations, therefore only one of these two modes should be selected or no
control of the press brake will be possible. If the mode selected on the CNC press controller is
the 2 Foot - 2 Foot dual operator mode, both operator stations will be allowed to initiate down
movement. If a single station mode is selected with modified down switch control, then the
CNC press controller must also provide information on which station is selected to initiate down
movement
,
using the station 02 variable from the CNC. The other station then has a modified
down switch control function that then prevents or stops this movement.
4.5.1.1
Option Selection
To select down switch option 5 during the PCSS configuration, set the initial value for down
switch option selection variable to
5
as described the F Series Technical Manual. This will
ensure that this option and all required inputs are initialised when the PCSS software is started.