LS-CS-M-023
PCSS-F Additions Technical Manual
Page 4-21
Original Language Version:
1.02
Released:
03/12/2013
4.2.2.5
CNC brake activation
This option monitors allows an external input to activate the emergency brakes by applying 24V
to this input. During brake activation the enable and quick stop signals will remain true.
Removing 24V from this input disables the brakes immediately.
The physical connection is made to X29 as shown in
below
CNC Brake Activation
X20
X21
X22
X23
X24
FIO04
–
CN7
1
2
3
4
5
X25
6
X26
7
X27
8
X28
9
X29
X30
X31
10
11
12
P20
24VDC
0VDC
13
14
15
Figure 4-16 CNC Brake activation
4.2.2.6
Back gauge Monitor
This option enables and monitors the back gauge output from the PCSS as shown in
below.
X00
X01
X02
Y04H
Y04L
FIO04
–
CN3
1
2
3
4
5
Y05
6
P00
7
24VDC
8
Enable Monitor
Enable Output
Figure 4-17: Option 7 Back gauge Monitor (CN3 - FIO04 Connections)