34
instructions regarding safety and operating proce-
dures.
6.2
BATTERY INSTALLATION AND
PREPARATION
These operations must be carried out by spe-
cialised personnel.
Make sure the two tanks are empty. If not, empty
them in accordance with the specific procedure.
Lift the recovery tank by 90°, making sure it is sta-
ble in that position. This provides access to the
battery compartment from the top.
Disconnect the Anderson connector of the battery
wiring from the Anderson connector of the machine
wiring. Always hold the connectors with the hands
and never pull on the cables.
Attach the battery wiring to the battery,
connecting the terminals only on the poles
marked with the same symbol (red wiring
“+”, black wiring “-“)! A battery short-circuit
may cause an explosion!
Run the cables toward the wiring outlet opening
(on one side of the box, only for Pb-Acid batteries),
tighten the terminals at the poles and cover them
with Vaseline.
Insert the battery putting the opening in the box
(only for the Pb-Acid battery) in a position to run
the electric wiring to the connector of the machine
wiring.
After checking that all the controls on the panel
are in position “0” or at rest, connect the battery
connector to the machine connector.
Close the battery compartment (lowering the
recovery tank) making sure not to crush any wires.
6.3 MACHINE
PREPARATION
Before starting to work, wear non-slip shoes,
gloves and any other personal protection device
indicated by the supplier of the detergent used or
considered necessary based on the operating en-
vironment.
☞
Do the following before starting to work. Refer
to the relative sections for a detailed description of
these steps:
Check the battery charge level and charge, if nec-
essary.
Mount the brushes or scraper disks (with the abra-
sive disks) that are suitable for the surface and
work involved.
Mount the squeegee, check that it is solidly at-
tached and connected to the suction hose and that
the drying straps are not too worn.
Make sure that the recovery tank is empty. If not,
empty it completely.
Check and completely close the detergent solution
release control.
Fill the detergent solution tank with a mix of clean
water and non-foaming detergent in an adequate
concentration through the rear hole. Leave 7 cm
between the mouth of the plug and the level of
the liquid.
☞
To avoid risks, become familiar with the machine
movements, carrying out test runs on a large sur-
face without obstacles.
To obtain the best results in terms of cleaning and
equipment service life, you should do the following
simple but important operations:
- Identify the work area, moving all possible obsta-
cles out of the way; if the surface is very extensive,
work in contiguous and parallel rectangular areas.
- Choose a straight work trajectory and begin work-
ing from the farthest area to avoid passing over
areas that have already been cleaned.
7. OPERATING INFORMATION
7.1 BATTERY
CHARGING
Prepare and check the battery charge according
to the instructions provided in the specific section.
Detach the battery connector (the one with the
handle) from the machine power connector and
connect it to the battery charger connector.
Do not connect the battery charger to the scrub-
ber-drier’s main wiring connector.
Hold the connectors with the hands; do not pull
them using the cables.
If the machine is equipped with Pb-Acid batteries,
charge only in a well-ventilated area, lift the top
tank and open the battery plugs.
Follow the steps indicated in the battery manu-
facturer’s operating and safety manual (see the
battery maintenance section).
If the machine is equipped with gel batteries
(maintenance free), follow the instructions indi-
cated here below.
If the machine is used regularly:
Always keep the batteries connected to the battery
charger when the machine is not being used.
If the machine is not used for extended time pe-
riods:
Charge the battery during the night after the last
work period, then disconnect the battery from the
battery charger.
Charge the battery during the night before using
the machine again.
Intermediate or incomplete charging while working
should be avoided.
If the machine is equipped with Pb-Acid batteries,
use a hydrometer to check the element liquid in-
tensity on a regular basis: if one or more elements
are discharged and the others fully charged, the
battery has been damaged and should be replaced
or repaired (refer to the battery service manual).
Close the element plugs and lower the top tank.
Hold the connectors with the hands; don’t pull
them using the cables.
Reconnect the battery connector to the connector
on the machine.
7.2
SQUEEGEE AND SPLASH GUARD
ASSEMBLY, DISASSEMBLY AND ADJUST-
Содержание COMFORT XXS
Страница 3: ...3 1 2 A B 1 5 4 2 7 4 5 6 9 8 3 3...
Страница 4: ...4 C 1 1 D 2 3...
Страница 5: ...5 3 3 2 1 4 6 7 6 7 1 2 5 E F 1...
Страница 6: ...6 H 2 G 1 3 3 1 4 2...
Страница 8: ...8 1 L 2 2 4 1 M 3...
Страница 9: ...9 N 1 2 3 6 7 5 4...
Страница 111: ......
Страница 115: ......
Страница 116: ...LAVORWASH S p a Via J F Kennedy 12 46020 Pegognaga MN ITALIA cod 7 504 0228 rev 01 12 2013...