![LAVAZZA Espresso Point Matinee 120V Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/lavazza/espresso-point-matinee-120v/espresso-point-matinee-120v_maintenance-manual_680616034.webp)
“E
SPRESSO
P
OINT MOD
. M
ATINÈE
” 120 V
C
OD
. 83312 / R
EL
. 1.00 / F
EBRUARY
2003
4
6/7
In the event of faults
The machine correctly delivers
coffee, steam or hot water but
there is water leakage inside
the structure.
If the leakage occurs between
the FAP press and chamber
• Perforated membrane.
If the leakage occurs between
the chamber and the integral
teflon coated plate
• Presence of scale.
• Membrane damaged on
the seal with the collar of
the teflon coated plate.
If the leak occurs between the
integral teflon coated plate and
the stainless steel labyrinth.
• Damaged or pinched
seals.
If the leak occurs on the
connection between the telfon
pipe and unit.
• Teflon pipe nut damaged
or loose.
• Damaged union elbow.
1
Dismantle the output unit
and replace the membrane.
1
Dismantle the output unit,
remove any scale deposits
and replace the membrane.
1
Dismantle the output unit
and fit new seals
1
Check tightenings.
2
Replace the teflon pipe if
necessary.
When requesting steam
delivery hot water comes out
of the jet and the pulsating
sound of the
pump cannot be heard.
When requesting delivery of
hot water, water comes out of
coffee spout.
1
Ensure that there are no
grains inside the solenoid-
valve body.
2
In the event that the defect
cannot be eliminated replace
the solenoid valve.
• The two-way solenoid valve
is blocked or defective.
1
Replace the card.
• Defective electronic card.
1
Clean the jet.
• Steam jet is clogged.