Loosen the pump support braces by unscrewing the
two screws shown in the figure.
First carry out the operations described in schedule 3.B
“Rear part preliminary maintenance operations”
Disconnect the two pump feed cables (
A
) and (
B
).
By using a 10 mm wrench, unscrew the pipe
tightening nut that connects the pump to the
solenoid valve.
Extract the pipe from the solenoid-valve.
2
3.6
1/2
Pump maintenance
Warning!
The wires A use safety fastons: to extract
press the faston cover as shown in the
figure.