554515_A_PUB_DATE_1_FEB_2014.DOC USER'S
MANUAL
13
N°
Failure
message
Failure
Action
Fault occurrence
E32
Verify Par
Verification fault
frequency inverter
parameters
Don’t start
At loading parameters
E35
Wrong Softw
Wrong software
version
Don’t start
New software version
E36
Imbalance
Unbalance
detection system
activated.
Reduction of spinning
sequence revolutions.
For Info only.
Spinning sequence
E37
No Drain Spr
Drain failure at the
Spray Sequence
Full stop + tumble
Spray Sequence
E38
No Recycle
The Tank with
recycle water is
empty
Warning at the End.
Front soap dispenser
Mach. only
Wash step
E39
Out of Soap
The Soap
Supplies are
running Out of Soap
For Info only
Wash step
E41
Service Due
Service Due
Warning
For Info only
Open door = reset
End cycle
E42
Connection
No Network
Connection
For Info only
Data Transfer Networking
E43
Voltage Par
Wrong Voltage
Range Selection
Make correct
selection
Configuration menu
E44
Model Type
Incorrect
selection of
machine type
Make correct
selection
Configuration menu
E80
SoapTimeOut
Incorrect signal for
liquid detergent
dispensing
Full stop + tumble.
Whole cycle
E81
No Reheat
Heating Failure
Full stop + tumble.
Wash Step
(Traceability only)
E82
No Refill
Refill failure
Full stop + request
for Continue
Wash Step
(Traceability only)
E83
Power
Interruption
No successful
wash cycle
termination
Info that the wash
cycle has to be
repeated.
Abnormal Cycle
Termination (Traceability
only)
E85
RTC Reset Bat
Real Time Clock,
No Battery or
battery low power
For Info only.
End cycle
(Traceability only)
E100
Weigh No
Comm
Communication
fault weighing
system
Full Stop Tumble
(machines with weighing
system only)
E101
Weigh Low
Weight machine is
too low
Don't Start
(machines with weighing
system only)
E102
Weigh High
Weight machine is
too high
Don't Start
(machines with weighing
system only)
E103
Weigh Balance
Weight is not
balanced over 4
load cell's.
Don't Start
(machines with weighing
system only)
E104
Weigh Overload
Weight on
individual load cell
exceeds max.
Full Stop Tumble
(machines with weighing
system only)
E300
-
E353
Mits Err
Specific Mitsubishi
Inverter Alarm
Full stop + safety time
Whole cycle
E500
-
E525
Memory Err
Memory Error
Full stop + safety time
Any time
Содержание LH-550