LAUNCH X-712 Wheel Aligner Operation Instructions
4-7
[Additional Measurement]: This interface provides an
operating platform for special measurement, which can
measure and display left lateral offset, right lateral offset,
axle offset, front setback, rear setback, track width
difference and wheelbase difference, etc. The interface
is as shown in Fig.4.21.
Fig.4.21
Click
pushbutton to select the parameters of
standard vehicle model. If the parameter values of
wheelbase and front/rear track width are contained in
the standard database, each angle value displayed on
the screen will automatically be converted into length
value with the unit of mm. The interface is as shown in
Fig.4.22.
Fig.4.22
Note: The system provides the dynamic
measurement and display for these special values,
but the measurement result will not be saved in the
database.
[HELP for vehicle adjustment]: Click this button, the
screen will pop up an interface of [HELP for vehicle
adjustment], the different toe-in and camber adjusting
methods for various vehicle models have been
enumerated in this interface for vehicle adjustment, the
operator can perform the toe-in and camber adjustment
operation according to the operating methods in the
HELP interface. The interface is as shown in Fig.4.23.
Fig.4.23
[Lift up the vehicle body]: Sometimes it is required to lift
the vehicle body up in order to be convenient to adjust
front/rear camber and caster. When the vehicle wheels
are lifted up, the inclinometers will move, and the
corresponding measured values will change, too. In this
case, please use Lifting Adjustment function. Click
button, and then lift up the vehicle body according
to the prompts on the screen. The software will
automatically compensate the offset of inclinometer in
order to realize accurate adjustment.
Fig.4.24
Attention: After adjustment, please remember to
click
button, and then put down the vehicle
body according to the prompts on the screen. If the
lift is not put down, it will be limited to select the
other interfaces (except for [Front axle measurement]
interface) as shown in Fig.4.25.
Содержание X-712
Страница 1: ...V2 01 000 2012 09 10 For X 712 X 712 Short Column X 712 Wall mounted X 712HD...
Страница 13: ...LAUNCH X 712 Wheel Aligner Structures 2 2 Fig 2 1 b X 712 Short Column Wheel Aligner...
Страница 14: ...LAUNCH X 712 Wheel Aligner Structures 2 3 Fig 2 1 c X 712 Wall mounted Wheel Aligner...
Страница 15: ...LAUNCH X 712 Wheel Aligner Structures 2 4 Fig 2 1 d X 712HD Wheel Aligner...