X-631 Wheel Aligner Product Service Manual Appendix 6
10-3
The length of the diagonal is 3035mm displayed on above example figure, and it is required to pat the calibration
bracket until the length data is about 3025mm displayed
Adjusting the Calibration Shaft Level
¾
We can use any one (the new one is preferred) of the probe rods of X-631+ wheel aligner for adjusting the calibration
shaft level.
¾
The two calibration shafts of the calibration frame can be adjusted level independently, now we take one of them as an
example to explain the level adjustment operation procedures.
1.
Install the probe rod on one end of the calibration shaft, and adjust the probe rod level according to the indication
of the mechanical level bubble of the probe rod, and then lock the probe rod well. Record the value of Camber 1
displayed on the screen of the probe rod;