X-631 Wheel Aligner Product Service Manual Appendix 6
10-5
Record the value of Camber 2 and adjust it to (Camber 1 + Camber 2)/2
3.
And then remove the probe rod and install it on another end of the same calibration shaft. Adjust the probe rod
level according to the indication of the mechanical level bubble of the probe rod, and then lock the probe rod well.
Record the value of Camber 1 displayed on the screen of the probe rod once more; now the value of Camber 1
should be changed to (Camber 1 + Camber 2)/2, too.
4.
That is to say that the value of Camber 1 should be equal to that of Camber 2 at last after adjustment. Otherwise,
please perform the adjustment operation again until the value of Camber 1 is equal to that of Camber 2. Of
course absolute equal is preferred (keep the difference between Camber 1 and Camber 2 within 2
″
at least).
Calibration
5.
Suppose that these 2 calibration shafts are of the 2 axles of vehicle (one is the front axle, and another is the rear
axle). Install four probe rods on the calibration frame in turn;