X-631 Wheel Aligner Product Service Manual Appendix 4
8-1
Appendix 4
Service Check List for X-631 Wheel Aligner
A. Check for Calibration File (Check.ini)
Rodaddr1=97 2d 83 FL Probe Rod Address
Rodaddr2=97 4d 83 FR Probe Rod Address
Rodaddr3=97 6d 83 RL Probe Rod Address
Rodaddr4=97 8d 83 RR Probe Rod Address
///***The address for the same set of probe rods: ** X* **, only X is changed, which should be 2, 4, 6, 8 or 3, 5, 7, 9 ***///
remotecontrol=5A 7B EA
pcaddr=52 52 52
SteerAngle=7
[zero]
x1=1004.5
1#CCD Zero coordinates
x2=1019.4
2#CCD Zero coordinates
x3=1033.6
3#CCD Zero coordinates
x4=1023.6
4#CCD Zero coordinates
x5=1031.6
5#CCD Zero coordinates
x6=1041.5
6#CCD Zero coordinates
x7=1015.5
7#CCD Zero coordinates
x8=1033.5
8#CCD Zero coordinates
///***If CCD is not replaced and recalibrated, its zero coordinates should be in accordance with the status before leaving
factory; After recalibrating, the difference between the current zero coordinates value and the value before leaving factory
cannot exceed 8 ***///
E=18
K1=-0.02759
K2=0.02759
K3=-0.02759
K4=-0.02759
K5=-0.02759
K6=-0.02759
K7=-0.02759
K8=0.02759
ToeK=.11
AV1=2192
Probe rod 1# (vertical) Clinometer zero coordinates
AV2=2088
Probe rod 2# (vertical) Clinometer zero coordinates
AV3=2087
Probe rod 3# (vertical) Clinometer zero coordinates
AV4=2193
Probe rod 4# (vertical) Clinometer zero coordinates
AH1=2048
Probe rod 1# (level) Clinometer zero coordinates
AH2=2025
Probe rod 2# (level) Clinometer zero coordinates
AH3=2110
Probe rod 3# (level) Clinometer zero coordinates
AH4=2038
Probe rod 4# (level) Clinometer zero coordinates
///***If clinometer is not replaced and recalibrated, its zero coordinates should be in accordance with the status before
leaving factory; After recalibrating, the difference between the current zero coordinates value and the value before leaving