Predátor P 56RX
52
Engine
roars to life
but does
not run
after starter
disconnecti
on
Speed regulator lever not
sufficiently in START
position
Set the lever to START
Fuel filter fouled
Change
Fuel supply line broken
Check and remedy
Error indication from control
elements in connection with
disconnecting automatics:
- no oil pressure
- filter fouled
- failure of alternator
- check entire fuel system
- check oil level
- check filter and clean or
replace it as
needed
- see Engine Manual
- change
SERVICE
SERVICE
Engine
turns off
Lack of fuel
Refill
Fuel pre-filter or fuel filter
fouled
Check and replace as needed
Blower belt broken
Change
Mechanical failure
Check and remedy
SERVICE
Engines
with
disconnecti
ng
automatics
STOP indication from
control elements:
- low oil pressure
- too high engine
temperature
- air filter fouled
- check oil level
- check cooling system
- check filter resp. clean it or
replace as
needed
Failure of electric
equipment:
- loose connections of wiring
- failure of alternator
- failure of relay
Check electric equipment and
particular components
Insufficient
engine
power
Insufficient fuel supply:
- lack of fuel
- fuel filter fouled
- insufficient fuel tank
venting
- fuel line leakage
- speed regulator lever does
not
remain in required position
- refill
- change filter
- check and remedy
- check and remedy
- unblock
Insufficient
engine
power, loss
of speed,
black
exhaust
fumes
Air filter fouled
Clean filter or replace it as
needed
Valve clearance not OK
Adjust
Failure of in injection nozzle See Engine Manual
Содержание Predator
Страница 1: ...Orig version 07 2020 OPERATING INSTRUCTIONS STUMP CUTTER Pred tor P56 RX...
Страница 5: ...Pred tor P 56RX 5...
Страница 6: ...Pred tor P 56RX 6...
Страница 54: ...Pred tor P 56RX 54 ELECTRIC CIRCUITRY...
Страница 55: ...Pred tor P 56RX 55...
Страница 56: ...Pred tor P 56RX 56 HYDRAULICS...
Страница 58: ...Pred tor P 56RX 58 Service Report...