ICS-TOUCH Instruction Manual
CEB00XXX-53-000
Page 16 of 43
Issue 4 19 January 2021
For further assistance on Lasermet products or for supply of suitable power supplies please contact
Lasermet through your local distributor or see the contact details at the end of this manual.
Option 1
One Way Illuminated Sign
The warning sign will come on when the ICS-6-SP is armed.
Figure 9.
Option 2
Two way Illuminated Warning Sign
The first warning sign will come on when the ICS-6-SP is powered. The first warning sign will go off
and the second warning sign will come on when the unit is armed. Note that in the case of the
Lasermet Miniature and Ultra 2-way warning signs, both indications are displayed in the same unit.
Figure 10.
Note regarding Sign Operation
If output devices such as LS-20 shutters or contactors are fitted, or if the laser has feedback contacts
which close to prove that it is in a safe condition and the feedback signal from such devices is taken
to the ‘Output Monitor’ terminals of the ICS-6-SP Control Unit, the sign green ‘Laser Off’ indication
will not be given if these devices are not proven to be in the safe condition or if they are removed
from the system.