ICS-TOUCH Instruction Manual
CEB00XXX-53-000
Page 15 of 43
Issue 4 19 January 2021
6.3 ICS-6-SP Illuminated Sign Control Output
Mains Voltage Warning Signs e.g. SlimJim and Low Profile Signs
Always check that the supply voltage rating of any signs matches your mains supply before
connecting. To avoid risk of shock always ensure the mains supply is isolated before making these
connections.
Option 1
One Way Illuminated Sign
The warning sign will come on when the ICS-6-SP is armed.
Figure 7.
Option 2
Two way Illuminated Warning Sign
The first warning sign will come on when the ICS-6-SP is powered. The first warning sign will go off
and the second warning sign will come on when the ‘Arm Laser’ button is pressed.
Figure 8.
Low Voltage DC Warning Signs
The following options are for 24VDC warning signs such as Lasermet’s Miniature and Ultra Warning
Signs. These signs must not be connected to the mains supply. If the power supply feeding the ICS-6-
SP is powerful enough the sign can be powered by spare terminals on the 24VDC Power terminal
block on the ICS. The ICS-6-SP needs 1A. Refer to the manual supplied with the sign for its current
requirements.