4
Summary of Evaluation of Compliance to EN ISO 13849-1:2015
To achieve a complete system performance level ‘e’ the system must be wired as described in this
manual using suitably rated door sensors and measures taken to minimise the effects of common
cause failures in the sensors and wiring which may be connected to the unit.
Achieved Characteristics:
Architecture
Category 4
Performance Level (PL)
PL = e
MTTFd
381 years
PFH [1/h]
2.47 x 10
-8
(Based on MTTFd being “capped” at 100 years)
Mission Time
20 years
Diagnostic Coverage (DC)
99% (HIGH)