![Laser Technology UltraLyte LR B Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/laser-technology/ultralyte-lr-b/ultralyte-lr-b_user-manual_3769404049.webp)
Section #6 – Serial Data Interface
47
Electronic Copy of LTI's UltraLyte LR B User's Manual - 2
nd
Edition © 2002
Speed/Range Data Message Format
Speed and range data downloaded in 20-20 Mode has the following
general format:
speed, range <CR><LF>
Speed
The speed measurement. Legal values are 000 to
199 MPH (000 to 320 KmH). If the target was
departing when the measurement was taken, the
number will be preceded by a minus sign.
Range
The range measurement. Legal values are 0000.0 to
9999.9 (unsigned).
<CR><LF>
A carriage return/line feed.
•
There are no units indicators. The values are in the
instrument’s default units.
•
If a measurement error occurs, the speed and range
values are replaced by an error code in the form Exx,
where xx is the error code. For more information about
Error Codes, see page 22.
Example Speed/Range Messages
English units:
50,700.0
Metric units:
80,213.4