L’ARTISTICO SRL |
35
Cod. 40297 | Rev. 09 | 05/2021 |
EN
Trouble:
Occurs when the pressostat switch detects a pressure / vacuum below the safety threshold, because of it:
Check the connections to the switch and that the outlet static pressure functions.
Check that the door is closed and the seals are not worn.
Check that the door of the overpressure, located above the combustion chamber is closed.
Check that the connecting channel and the flue are connected and perfectly clean.
Check that the flue is not obstructed.
Solution:
Check the causes.
If the problem persists, contact technical support.
Trouble:
The radio control does not communicate with the control unit, because of it:
Check the main switch on appliance’s rear panel being
Check fuses (4A) located near the main switch and on the electronic board .
Loss of remote control synchronization (see section 3).
Solution:
Check the causes. If the problem persists, contact technical support.
only for hydro
devices
Trouble:
Pressure of water out of permissible limits, error if <0.5 bar and if> 2.5 bar
Solution:
Check the water pressure
Check the correct operation of the Pressure Transducer.
If the problem persists, contact the plumbing technician who has run the system.
only for hydro
devices
Trouble:
Water temperature too high.
Solution:
The unit will automatically turn off if the water temperature exceeds 90 ° C and on again when the water
temperature is within the standard values.
If the problem persists, contact the plumbing technician who has run the system.
only models with
sealed chamber,
type B
Trouble:
It occurs when left open the loading door of the pellet tank for more than 180 seconds. The display will scroll
the following message and the device is in power off..
Solution:
Close the pellet loading door.
If the problem persists, contact technical support.