L’ARTISTICO SRL |
32
Cod. 40297 | Rev. 09 | 05/2021 |
EN
24. CONNECTION OF THE REMOTE CONTROL TO THE DEVICE (optional).
In case radio data transmission between remote control and appliance doesn’t work properly
(high electromagnetic pollution) it is possible linking the remote control with a dedicated cable
(to be ordered as option).
Warning: if you connect the transmitter to the stove, you must
REMOVE THE BATTERIES from the remote control, as the power supply
required to operate is taken from the device.
25. INSTRUCTIONS FOR USING THE REAR EMERGENCY CONTROL PANEL
Warning: for pellet fireplaces it must be placed in a visible, accessible place and away from heat sources.
The
rear control panel is designed to be used in emergency cases only, i.e. remote control failure or do not remember where it is. The hearth of the
system is the remote control. For this reason only 2 functions can be operated from the real panel: on/off and power output setting on steps 2 or 5. It
is not possible setting the room temperature.
› Button 3
- On / Off
To turn the unit on, press the button for about 3 seconds, until the LED turns green
To switch the unit off: press the button for about 3 seconds, until the green LED flashes.
. When the stove finishes the
cleaning cycle, the green LED will turn off.
› Covering led
This led confirms the remote control transmission has been correctly covered.
› Alarm Led
This led lights on when a failure has been detected. The remote control is necessary to display the failure that did occur.
In case the appliance went out of pellet press and keep button 3 to reset the alarm till red led goes off and green led
starts flashing. In all other cases do not start the appliance but call for service.
› Button 2
- Power output 5
Allows setting the power output on level 5.
Press and keep button 2 for 3 seconds till the relevant led light yellow .
› Button 1
- Power output 2
Allows setting the power output on level 2.
Press and keep button 1 for 3 seconds till the relevant led light yellow .
26. EXTERNAL THERMOSTAT (OPTIONAL)
The standard unit controls the room temperature by means of a probe that adjusts the power according to the set temperature. The probe is
positioned in the remote control and measures the temperature in the place where the remote control is located. The user can choose to use an
external thermostat, connected directly to the motherboard, whose sensor can be located in the most suitable place. In case of an external
thermostat, it is necessary to use a 'normally open' type. Contact an authorized technician and follow the following instructions:
turn the unit off at the main switch and disconnect the power cable;
remove the insert from the compartment and access the motherboard: referring to the wiring diagram, connect the two thermostat wires to the
respective terminals TERM of the board
(WARNING: it is a clean contact, NO 230 V);
refit everything.
Then set as follows:
in case of external thermostat
: Set a temperature of 7°C on the remote control and adjust the external thermostat setting as
desired;
in case of external chronothermostat
: Set a temperature of 7°C on the remote control and adjust the external chronothermostat
setting as desired.
It is compulsory to disable the chrono function in menu 03 and set the STANDBY
function to ON
. When the set temperature is reached, the insert will shut down and not go to modulation. In any case, it is advisable to
use the insert time programming function and only the external chronothermostat setting function. This will avoid creating conflicts between the
insert programming and that of the chronothermostat
Check correct operation