Troubleshooting Manual 

System not turning on (sequence A) 

Check the battery voltage (should be >24.7).

Turn on the power switch.

Turn on the disconnect switch.

Turn on the solar breaker.

Let the batteries charge for 5 hours. 

System does 

not Charge (sunny weather)

 

Turn on the power switch.

Turn on the disconnect switch.

Turn on the solar breaker.

check the solar charge controller display.

If the battery does not hold Voltage, replace them with equivalent (200Ah) batteries. 

Mast do not 

extend 

Turn on the power switch

Turn on the disconnect switch

Move the pressure valve to up position.

Switch on the pump switch.

check the pressure gauge.

If the pressure does not build up check for leakage in the pressure line. 

Lights do 

not turn on 

Follow sequence A and than turn on the inverter switch.

Switch on the light switch 1 and switch2.

Check the plug connection on the light head.

Check the voltage at terminals( should be 120) at the following locations 

A.

Inverter Output

B.

Light head plug

C.

Light head junction box.

If the inverter fails check for blown fuse on the inverter and replace with equivalent fuse rating. 

Содержание SPLT IVT-12VDC-1000VA-120VAC Series

Страница 1: ...S RATED VOLTAGE TO PREVENT WIRING DAMAGE OR ABRASION DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP OBJECTS SUITABLE FOR DAMP LOCATIONS IMPORTANT READ CAREFULLY BEFORE INSTALLING THIS FIXTURE S...

Страница 2: ...equipped with positive and negative probes which allows the meter to get a DC voltage reading from the battery Multimeters give a DC voltage reading from your batteries Look up the battery s model num...

Страница 3: ...but wet use either a window wiper or a microfiber cloth on a handle to dry the panels Making sure there is not residue on your panels is an important part of solar panel maintenance and cleaning Resid...

Страница 4: ...hat cleaning and lubrication are needed can be A noticeable gritty film on the exterior surfaces of the mast sections rratic extension or retraction of the mast Noisy operation of the mast ticking of...

Страница 5: ...icant 8 Lower the mast completely Allow several minutes for the lubricant to settle and spread around the wear ring and seal at the bottom of each mast section 9 Extend the mast again one section at a...

Страница 6: ...intle having trailer GVW rating if needed Tires Check tire pressure when cold and inflate as needed Also check for damage Wheels lug nuts or bolts and hub Check for tightness and tighten For new or re...

Страница 7: ...ck Drop Leg if equipped Grease gears at the top Structure Frame Members Inspect all frame members bolts and rivets Repair or replace damaged worn or broken parts Structure Welds Inspect and repair all...

Страница 8: ...battery does not hold Voltage replace them with equivalent 200Ah batteries Mast do not extend Turn on the power switch Turn on the disconnect switch Move the pressure valve to up position Switch on th...

Страница 9: ...or runs continuously and air flow lower than normal 1 Excessive air usage 2 Loose connections 3 Worn piston ring or inlet valve 4 Clogged air filter element 1 Decrease air usage 2 Check all connection...

Страница 10: ...itch to reset 4 Replace pressure switch Thermal overload protector cuts out repeatedly 1 Lack of proper ventilation or ambient temperature is too high 2 Compressor valves failed 1 Move compressor to w...

Страница 11: ...place out of the reach of children when not in use Inspect for good working condition prior to storage and before re use REPLACEMENT PARTS The SPLT xx IVT 12VDC 1000VA 120VAC is designed to provide ye...

Отзывы: