SPLT-xx-IVT-12VDC-1000VA-120VAC
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
10
of
11
4. Faulty pressure switch (if
hooked up to a pressure
switch).
section for correct fuse
amperage)
3. Let compressor cool off for
about 30 minutes to allow
thermal overload switch to
reset.
4. Replace pressure switch
Thermal overload
protector cuts out repeatedly
1. Lack of proper ventilation
or
ambient temperature is too
high.
2. Compressor valves failed
1. Move compressor to well
ventilated area, or area with
lower ambient temperature
2. Replace compressor
Excessive knocking
or rattling
1. Loose mounting bolts
2. Worn bearing on eccentric
or
motor shaft
3. Cylinder or piston ring is
worn
1. Tighten bolts
2. Replace bearing or piston
assembly
3. Replace piston or
compressor