SPLT-xx-IVT-12VDC-1000VA-120VAC
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
5
of
11
4.
Dampen a rag with a non-abrasive cleanser or solvent such as lacquer thinner to wipe down
the extended
mast section. Do not allow the cleaning fluid or solvent to run down inside the
collar.
5.
Repeat steps 3 and 4 for the next larger mast section.
6.
Inject approximately 1/2 oz. of Mast Lubricant or a lightweight machine oil into the air holes of
the exposed
mast section.
7.
Repeat steps 3, 4 and 6 for each of the remaining mast sections. The larger diameter
sections should be
injected with approximately 1 oz. of lubricant.
8.
Lower the mast completely. Allow several minutes for the lubricant to settle and spread
around the wear
ring and seal at the bottom of each mast section.
9.
Extend the mast again one section at a time in the same sequence (smallest to largest). Wipe
off any
excess lubricant that flows out of the air holes.
Tires:
Check the tires pressure regularly and before transport the solar trailer. Low pressure in tires could cause the
solar trailer to not level correctly. Fill the tires up with air if the pressure is low. Replace your tires if the tread
worn out.
Trailer’s brake lights & license plate lights:
Check the brake lights, make sure all brake lights work properly on the trailer before transport. If light does not
turn on, check all wire connections to the light make sure all connections are good. If light still not turn on,
change light bulb.