44429367
Montageanleitung
Assembly instruction
Gültig ab/
valid from
08.03.2021
EPIC
®
LS1.5 Vierdorn Crimpzange
EPIC
®
LS1.5 4-indent crimping liers
Dokument/
document
: L44429367DE_EN
Version/
version
: 00
Seite 6 von 8
page 6 of 8
Wir behalten uns alle Rechte gemäß DIN ISO 16016 vor.
Changing the battery
The service life of the battery for the digital display is approximately one year, depending on how often it is used. To
change the battery (type CR2025, 3 VOLT), the battery holder is pulled out so that the battery can be removed and
exchanged. Before inserting the battery,
make sure you set the pliers to the stop at the lower setting point.
How to further proceed is described in the section
"Calibrating the reference value".
Dispose of used batteries at
approved recycling centers.
Calibrating the pliers
The crimping pliers may only be calibrated by authorized skilled
personnel, since improper calibration can lead to incorrect
crimping.
Adjust the crimp arbors to a setting dimension of 2 mm: Using
the adjustment knob, set the crimp arbors so that the enclosed
gauge can move between the crimp arbors without play. Please
note that a larger gauge dimension must always be selected
than that to be set, e.g. select 2.4 mm and adjust down to
gauge dimension 2.0 mm.
Keep the "ON/OFF" button pressed and press the "MODE"
button using the gauge. Keep the "MODE" pressed for at least
5 seconds. Release the "MODE" button after 5 seconds and
then the "ON/OFF" button.
The digital display automatically jumps to the gauge value 2.0
mm. The pliers are adjusted and ready for the crimping
parameters to be set.
Wear monitoring
Every tool is subject to wear, even when used as intended. This wear is tolerable within certain limits and is
compensated during each calibration. Press the "Mode" button for 10 seconds (range: 8 to 15 s) to call up the
current tool status and to display the numerical output on the pliers. The following values are output consecutively:
Serial number – current wear value – position value of the lower stop of the unworn pliers (fixed value, specific to
pliers) – number of previous calibrations carried out.
The mechanical stop at the lower setting point serves as a reference value for calculating the current wear value.
The value is permanently stored in the tool memory and cannot be changed. Every time the battery is changed,
calibration must be carried out using this reference value. To do this, follow this procedure: