APPENDIX C
OPTIFLAM
TM
combustion controller (optional) (continued)
• TEMPERATURE WARNING MESSAGES
The program screen may also display two warning messages: one to indicate a HIGH TEMPERATURE in the
combustion chamber (Illustration 7), and the other to indicate a faulty TEMPERATURE SENSOR (Illustration 8).
Illustration 7
Illustration 8
Combustion chamber HIGH TEMPERATURE warning
This warning message appears when an overly large
reload brings the combustion chamber temperature
above 200 °F (93 °C) from the set point temperature
for an extended period of time.
When this situation occurs, the OPTIFLAM
TM
takes
appropriate measures in AUTOMATIC mode to reduce
the temperature as quickly as possible.
For the set point temperature, see below
5. AUTOMATIC
MODE, 5.1 Step 1, point 1.
Faulty TEMPERATURE SENSOR alarm
The OPTIFLAM
TM
uses the combustion chamber
temperature sensor to maintain the chamber
temperature at the designated set point.
When a sensor malfunction is detected, the program
can no longer function correctly and it is necessary to
switch to MANUAL mode.