background image

Lantronix

 

 

x6310 ION POTS Media Converter User Guide 

33818 Rev. A 

    

https://www.lantronix.com/

  

Page 

6

 of 

39

 

x6310 Features 

  Audio transmission of voice grade signals  

  Supports ringing at distant end  

  Supports Caller ID  

  Configurable worldwide country formats  

  Must be deployed in pairs:  

o

  ION chassis card and stand-alone unit  

o

  ION chassis card and ION chassis card  

o

  Stand-alone unit and stand-alone unit  

  Single product configurable to FXO Mode or FXS Mode 

  Automatic Ring Down supported when both converters are configured to FXS Mode  

  SFP based product:  

o

  Uses Gigabit Ethernet SFP Modules  

o

  Lantronix offers a wide variety of SFP modules to support multimode or single-mode fiber, as well as 

dual or single strand fiber installations  

  SNMP Management supported when installed in a managed ION chassis  

  Supports remote management of paired unit, in-band, over the fiber  

  Electrical interface is provided through an RJ-11 female connector  

  Field upgradeable firmware  

  Only supports analog POTS lines  

  Compatible with traditional telephone modems  

x6310 Specifications 

Standards 

FCC Part 68 

ETSI ES 203-021 (TBR21) 

ISED CS-03 

Analog Port  

RJ11 Connector 

FXS Mode 

Impedance: 600 ohms 

REN: 1.0  

Ring Cadence: 25 Hz 

FXO Mode 

Impedance: 600 ohms 

Battery Source: 48 VDC +/- 5V 

Ringing Supply: 90Vp-p 

Ring Frequency: 16-65 Hz 

DIP Switches 

DIP switches to set the Emulation Mode and Region Codes: 

SW1 Up = FXO; Down = FXS 

SW2 Up = Normal; Down = FXS Reversed 

SW3 Up = U-Law; Down = A-Law 

SW4 not used 

SW5 – SW8 Country Code Select  

 

 

Содержание 6310 Series

Страница 1: ...x6310 ION POTS Media Converters POTS 2 Wire Copper to Fiber Install Guide Part Number 33818 Revision A March 2022 ...

Страница 2: ...0 1312 Email techsupport transition com Sales Offices For a current list of our domestic and international sales offices go to www lantronix com about contact Disclaimer All information contained herein is provided AS IS Lantronix undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or o...

Страница 3: ...oop Start Operation 14 Idle State On hook 14 Telephone In use Off hook 14 Central Office CO Rings the Telephone 14 Copper Cable Category 1 14 Software Installation and Operation 15 Remote Management 15 Firmware Upgrade C6310 SIC Only 15 CLI Commands 16 General 16 Command Line Editing 16 Display Similar Commands 16 Partial Keyword Lookup 16 Recall Commands 17 Commands Effect on Stored Files 17 Web ...

Страница 4: ...lephone Company s Network 34 Problems with the Equipment 34 Repairs to the Equipment 34 Party Lines 34 Alarm Dialing Equipment 35 Industry Canada Requirement 35 Industry Canada Representative 35 6 Compliance Information 36 FCC Regulations 36 Canadian Regulations 36 TBR21 ETSI ES 203 021 37 ICES 003 37 Declaration of Conformity 37 Recording Model Information and System Information 38 ...

Страница 5: ... Pair RJ 11 5 km 3 1 mi to open SFP Slot Fiber Type Optical Wavelength Transmission Distance and Link Budget all based on selected SFP module Must be used in pairs S6310 3340 Stand alone media converter twisted Pair RJ 11 5 km 3 1 mi to Open SFP Slot Fiber Type Optical Wavelength Transmission Distance and Link Budget all based on selected SFP module Power Supply Included To order the corresponding...

Страница 6: ...pport multimode or single mode fiber as well as dual or single strand fiber installations SNMP Management supported when installed in a managed ION chassis Supports remote management of paired unit in band over the fiber Electrical interface is provided through an RJ 11 female connector Field upgradeable firmware Only supports analog POTS lines Compatible with traditional telephone modems x6310 Sp...

Страница 7: ...onsumption 2 0 Watts without the SFP Power Supply S6310 External AC DC provided 12 VDC 1 25A Output Unregulated UL Listed Environment Environment specs are dependent on the chassis chosen Operating Temp 0 to 50 degrees C Storage Temp 40 to 85 degrees C Humidity 5 to 95 non condensing Altitude 0 10 000 ft Weight 1 lb 0 45 kg Compliance Emissions EN55032 Class A FCC Part 15 Class A Immunity EN55024 ...

Страница 8: ...t below Contact your sales representative if any item is missing or damaged See the ION x6310 webpage for optional accessories features specifications ordering information etc One C6310 Slide In Card in Anti static bag or one S6310 Stand alone Converter One Insert Card Four Rubber Feet S6310 only Optional accessories may be packaged separately Application Examples FXO Setup FXS and FXS R Setup ...

Страница 9: ...www lantronix com Page 9 of 39 2 Installation CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the jumpers Failure to observe this caution could result in damage to or failure of the module PC Board Layout The PCB is shown below ...

Страница 10: ... Macao Mexico Peru Russia Saudi Arabia Singapore Taiwan UAE USA Yemen 2 1110 TBR21 Austria Belgium Denmark Finland France Germany Greece Iceland Ireland Italy Luxembourg Netherlands Norway Portugal Spain Sweden Switzerland United Kingdom Vietnam 3 1101 Austria Bahrain Belgium Croatia Cyprus Czech Republic Denmark Egypt Finland France Germany Hungary Iceland Ireland Israel Italy Latvia Lebanon Luxe...

Страница 11: ...d and installed with chassis power on 1 Locate an empty slot in the ION System chassis 2 Grasp the edges of the card by its front panel 3 Align the card with the upper and lower slot guides and carefully insert the card into the slot 4 Firmly seat the card against the chassis back panel 5 Push in and rotate clockwise the panel fastener screw to secure the card to the chassis see Chassis Installati...

Страница 12: ...th the label facing correctly 2 Carefully slide the SFP device into the slot aligning it with the internal installation guides 3 Ensure that the SFP device is firmly seated against the internal mating connector 4 Connect the fiber cable to the fiber port connector of the SFP device Removing SFPs Caution Be careful when removing the SFP from a device Some SFP transceiver module temperatures may exc...

Страница 13: ...phone terminal equipment or FXO Automatic Ring down Configuration Automatic Ring Down ARD is a dedicated point to point voice system When one telephone is taken off hook the other telephone rings without the need to dial Two modules connected via the fiber ports a telephone device at each end is the requirement for this configuration Automatic Ring Down is supported when both converters are config...

Страница 14: ...k 1 The CO applies a battery voltage to the ring lead and monitors the tip ring current for closure of the tip ring 2 The telephone device draws less than 10 μA of current from the line Telephone In use Off hook 1 The customer takes the telephone device off hook drawing a minimum of 20 mA of current 2 The CO senses the tip ring current and issues a dial tone on the line 3 Communication can now beg...

Страница 15: ...is while the SA cannot be managed on its own Management of the remote converter SA or SIC in band over the fiber by the local chassis based managed converter is supported The x6310 converters can be deployed as follows SA to SA No Management of local or remote Card to SA Local SIC manages remote SA Card to Card Local SIC manages remote SIC Note See the IONMM User Guide for information on how to In...

Страница 16: ...on describes how to enter CLI commands A CLI command is a series of keywords and arguments Keywords identify a command and arguments specify configuration parameters Display Similar Commands C1 S7 L1D show ether tab key config loopback security statistics tdr Use the key after a partial CLI command entry to display all of the available commands that start with show ether but in a single column C1 ...

Страница 17: ...remove temporary files e g configuration backup files Syslog file A Factory Reset also removes the permanent settings e g configuration files HTTPS certification file SSH key The following CLI commands can cause a loss of files reboot warm start the system reset reset factory configuration See the specific command description for additional information Command show card info Description Display ca...

Страница 18: ...9 TestLab C1 S11 L1P1 show ether config Port 13340 TP port Link operation status up Port mode RJ 11 ION219 TestLab C1 S11 L1P1 go c 1 s 11 l1p 2 ION219 TestLab C1 S11 L1P2 show ether config Port 23340 FIBER port Link operation status up Port mode SFP Slot Speed 1Gb ION219 TestLab C1 S11 L1P2 Command show system information Description Display current system information Syntax show system informati...

Страница 19: ...nter The ION System Sign in screen displays Note If your system uses a security protocol e g RADIUS SSH etc you must enter the login and password required by that protocol 4 Type a User Name of up to 64 characters the default is ION all upper case letters 5 Type the Password the default is private all lower case letters 6 Click the Sign in button or press the Enter key The opening screen displays ...

Страница 20: ...meter descriptions Model Information Serial Number The device serial number e g 4545 Model The device model e g C6310 3340 Software Revision The current version of device software e g 2 0 0 Hardware Revision The current version of device hardware e g 1 0 0 Bootloader Revision The current device bootloader version e g 0 1 10 FPGA Revision The current device Field Programmable Gate Array version e g...

Страница 21: ...et by hardware DIP Switch FXS FXS R or FXO FXS Foreign exchange station mode of operation This unit connects to a telephone line or PBX and acts as a telephone FXS Mode module and can detect ringing voltages FXS R FXS Reverse mode of operation FXS is Line mode and FXS R is Line mode reversed If one phone is connected directly to the local C6310 and another phone is connected directly to the remote...

Страница 22: ... below Note that read only parameters are greyed out Parameter descriptions Circuit ID Entry field for the port circuit ID Port Configuration Hook Status The current Hook status OnHook or OffHook Connector Type The current type of connector RJ 11 Buttons Refresh Click to update the page data Save Click to save any parameter changes to the running config file Help Click to display the related onlin...

Страница 23: ...ly parameters are greyed out Parameter descriptions Circuit ID Entry field for the port circuit ID Port Configuration Link Status The current Link status Up or Down Connector Type The current type of connector SFP Slot Fiber Speed The current speed of Fiber Port 2 e g 1Gb Buttons Refresh Click to update the page data Save Click to save any parameter changes to the running config file Help Click to...

Страница 24: ...0 0 Bootloader Revision The current device bootloader version e g 0 1 10 FPGA Revision The current device Field Programmable Gate Array version e g 1 0 1 System Configuration System Name Field to enter a descriptive name for the device System Up Time The amount of time that the device has been running in days hours minutes seconds tenths of a second format e g 1 19 41 41 00 Configuration Mode The ...

Страница 25: ...tly to the remote S6310 one must be in FXS mode and the other must be in FXS R mode FXO Foreign exchange office mode of operation This unit is the reciprocal unit acting as a Central Office CO connected to a telephone device FXO Mode module Country Code Displays the region selected via DIP switch The default is Region 1 USA See 8 Position DIP Switch on page 10 Buttons Uptime Reset Click to reset z...

Страница 26: ... parameters are greyed out Parameter descriptions Circuit ID Entry field for the port circuit ID Link Status The current port link status Up or Down Connector Type The current port connector type SFP Slot Fiber Speed The current port Fiber speed e g 1Gb Buttons Refresh Click to update the page data Save Click to save any parameter changes to the running config file Help Click to display the relate...

Страница 27: ...er is below specified threshold Fiber trap intrusion may be in progress displays follow your organization s policy and procedure for intrusion detection DMI can be configured in the NID using either the CLI or Web method The Fiber Port 2 DMI tab parameters are shown and described below Note that read only parameters are greyed out The Interface Characteristics Diagnostic Monitoring and Supported M...

Страница 28: ... The Nominal transmitter output wavelength at room temperature measured wavelength The unit of measure is nanometers for example 1550 nm or 850 nm Diagnostic Monitoring Receive Power uW ionDMIRxPowerLevel 16 Receive power measured power measurement on local fiber measured in microwatts for example 11 µW Receive Power dBM ionDMIRxPowerLevel 16 Receive power measured signal strength on local fiber m...

Страница 29: ...mal 1 Not Supported 2 Low Warn 3 High Warn 4 Low Alarm 6 High Alarm 7 Transmit Power uW ionDMITxPowerLevel 14 Measured transmit power on local fiber measured in microwatts For example 240 µW microwatts Transmit Power dBM ionDMITxPowerLevel 14 Transmit power on local fiber measured in dBM decibels relative to one milliwatt which defines signal strength For example 2 291 dBM Transmit Power Alarm ion...

Страница 30: ... TN DWDM SFP 5012 the 5012 indicates 1550 12 nm center wavelength laser support Revision ionDMIInfoEntry 21 A 4 byte field that contains ASCII characters defining the vendor product revision number A value of all zeroes in the 4 byte field indicates that the vendor revision is unspecified For example 2 0 Serial Number ionDMIInfoEntry 22 A 16 character field that contains ASCII characters defining ...

Страница 31: ...onverter User Guide 33818 Rev A https www lantronix com Page 31 of 39 Buttons Refresh Click to update the page data Save Click to save any parameter changes to the running config file Help Click to display the related online Help page ...

Страница 32: ...chnical Support YES Proceed to step 3 3 Is the ACTC activity LED On Off or Blinking NO Ensure that the local unit is off hook Contact Technical Support YES Contact Technical Support 4 Are the Link status LEDs lit NO Check for power and verify the links YES Proceed to step 5 5 Are the DIP switch settings correct NO See 8 Position DIP Switch on page 10 YES Proceed to step 6 6 Make sure that the func...

Страница 33: ...3818 Rev A https www lantronix com Page 33 of 39 Box Labels and Device Labels The labels can provide information that can help the Tech Support Specialist LANTRONIX M N x6310 3340 US LTXOT10Ax6310 Complies with 47CFR Part 68 USOC jack RJ11C Made in TAIWAN ...

Страница 34: ...e connected to a line as determined by the total RENs contact the local telephone company See https www fcc gov sites default files part 68 faqs pdf Harm to the Telephone Network If the x6310 causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice is not practical the telephone company will...

Страница 35: ...nsist of any combination of devices subject only to the requirement that the sum of the RENs of all devices does not exceed five This product meets the applicable Industry Canada technical specifications L indice d équivalence de la sonnerie IES sert à indiquer le nombre maximal de terminaux qui peuvent être raccordés à une interface téléphonique La terminaison d une interface peut consister en un...

Страница 36: ...n accredited by National Institute of Standards and Technology NIST can be viewed at http ts nist gov ts htdocs 210 gsig tcb program htm Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radi...

Страница 37: ...Declaration of Conformity Manufacture s Name Lantronix Inc Manufacturer s Address 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Declares that the products S6310 C6310 Conform to the following Product Regulations FCC Part 15 Class A EN 55032 2012 EN 55024 2010 Directive 2014 30 EU Directive 2015 863 EU Low Voltage Directive 2014 35 EU IEC EN 60950 1 2006 A2 2013 2011 65 EU EN 50581 2012 Wit...

Страница 38: ...________________ __________________________________________________________________________________________ __________________________________________________________________________________________ A description of any action s already taken to resolve the problem e g changing switch mode rebooting etc __________________________________________________________________________________________ ____...

Страница 39: ... 7535 Irvine Center Drive Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or techsupport transition com Sales Offices For a current list of our domestic and international sales offices go to the Lantronix web site at www lantronix com about contact ...

Отзывы: