Lantronix
x6310 ION POTS Media Converter User Guide
33818 Rev. A
Page
17
of
39
Recall Commands
To recall recently entered commands from the command history, perform one of the optional actions below:
Ctrl-P
or
Up arrow
(
↑
)
key: Recall commands in the history buffer, beginning with the most recent command.
Repeat the key sequence to recall successively older commands.
Ctrl-N
or
Down arrow
(
↓
)
key: Return to more recent commands in the history buffer after recalling commands
with Ctrl-P or the Up arrow key. Repeat the key sequence to recall successively more recent commands.
Commands Effect on Stored Files
Note
: Certain CLI commands affect important stored files. Doing a reboot, restart or upgrade of the C6310, a
power restart of the chassis, or a reset to factory defaults will remove temporary files (e.g., configuration backup
files, Syslog file). A Factory Reset also removes the permanent settings (e.g., configuration files, HTTPS
certification file, SSH key). The following CLI commands can cause a loss of files:
•
reboot
:
warm start the system.
•
reset
:
reset factory configuration.
See the specific command description for additional information.
Command:
show card info
Description:
Display card information.
Syntax:
show card info
<cr>
Parameters:
None
Example:
ION219-TestLab C1|S18|L1D>
go s=11 l1d
ION219-TestLab C1|S11|L1D>
show card info
System name:
Uptime: 22:38:12
MAC: 00-c0-f2-8f-81-40
Number of ports: 2
Serial number: 4545
Config mode: software
Software: 2.0.0
Bootloader: 0.1.10
Hardware: 1.0.0
FPGA rev: 1.0.1
ION219-TestLab C1|S11|L1D>
Command:
show pots status
Description:
Display device’s current POTS status.
Syntax:
show pots status
<cr>
Parameters:
None
Example:
ION219-TestLab C1|S11|L1D>
show pots status
C6310 Emulation Mode: FXO
C6310 Country Code: Region 1 (USA)