Installation
8
INSTALLATION
DANGER:
THIS APPLIANCE MUST BE GROUNDED AT THE
TERMINAL PROVIDED. FAILURE TO GROUND THE
APPLIANCE COULD RESULT IN ELECTROCUTION AND
DEATH.
WARNING:
INSTALLATION OF THE UNIT MUST BE DONE BY
PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY.
IMPROPER INSTALLATION CAN CAUSE INJURY TO
PERSONNEL AND/OR DAMAGE TO EQUIPMENT. UNIT
MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE:
The data plate is located right of range top controls and
behind the circuit breaker door on oven. The oven voltage,
wattage, serial number, wire size, and clearance
specifications are on the data plate. This information
should be carefully read and understood before
proceeding with the installation.
NOTICE:
The installation of any components such as a vent hood,
grease extractors, fire extinguisher systems, must
conform to their applicable National, State and locally
recognized installation standards
.
Electrical Connection
All connections can be made through 1 3/4” hole in the bottom of the oven.
Connections should be made to the wires coming form the circuit breaker.
WARNING:
MAKE SURE THE MAIN POWER SUPPLY TO THE
RANGE IS TURNED OFF AT THE SOURCE PRIOR
TO CONNECTING POWER TO THE RANGE.
The range can now be connected to power.
CAUTION:
BE SURE THE POWER SUPPLY VOLTAGE
MATCHES THE VOLTAGE SPECIFIED ON THE
NAMEPLATE LOCATED ON THE FRONT OF THE
RANGE.
Three Phase
Single Phase
208 Volt
240 Volt
480 Volt
208 V
240 V
Total
K.W.
Conn
L1 L2 L3 L1 L2 L3 L1 L2 L3 L1 L2
37.0
108.0 100.0 100.0 93.9 86.7 86.7 46.9 43.3 43.3 177.9 154.2
PHASING
POWER
SUPPLY
TERMINAL
BLOCK
RANGE
TOP
L1 1,3,5,7,9
SINGLE
PHASE
L2 2,4,6,8,10
L1 1,4,7,10
L2 2,5,8
THREE
PHASE
L3 3,6,9