PARTS LIST 

 

MM36C-I-CLS  

 

Item # 

Description 

Part Number Qty 

1 Body 

N/A 

Leg 4” w/ Round Adjustable Toe 

72500-12 

Lamp Bottom Support Left Hand 

MMCL-141 

4 Reflector 

Clip 

MMCL-181 

3 foot Reflector 

MMCL-178 

Lamp Bottom Support Right Hand 

MMCL-142 

7 Rack 

Holder 

MMCL-169 

8 Shelf 

Pivot 

MMCL-166 

9 Access 

Panel 

MMCL-153 

10 Bottom 

Assembly 

MMCL-144 

11 Tinnerman 

Clip 

20602-01 

12 Body 

Wrap 

MMCL-175 

13 Insulation 

Kit 

60106-51 

14 MM36 

Rack 

50200-14 

15 

Black Threaded Boot for Metal Toggle Switch 

30303-15 

16 

Metal Handle Toggle Switch, On-On, DPDT 

30303-14 

17 Panel 

Assembly 

MMCL-191-1 

18 

2 Pole Contactor, 30 Amp, 208/240 VAC 

30701-02 

19 

Small 3 Pole Terminal Block, 95 Amp 

30500-09 

20 

Quartz Heater, 120V, 1800 Watt 

11160-22 

21 

12 Gauge Tan Wire, UL5256, 250

°

31102-02 14 

FT 

22 

18 Gauge Tan Wire, UL5256, 250

°

31102-03 

2 FT  

23 

14 Gauge Tan Wire, UL5335, 450

°

31103-02 2 

FT 

24 

3 foot Back 

MMCL-183 

25 

Insulation for MM36 Wall Mount Kit 

MM-189 

26 

3 foot Wall Bracket 

MMCL-186 

 

 

50200-14
30303-15
30303-14

30701-02
30500-09
11160-22
31102-02
31102-03

Содержание MM36C-I-CLS

Страница 1: ...y 6500 Merrill Creek Parkway Everett WA 98203 Phone 425 349 2400 Fax 425 349 2733 WWW LANGWORLD COM Copyright 2000 Installation Operation Maintenance Troubleshooting Model MM36C I CLS Electric Cruise...

Страница 2: ...NING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALL...

Страница 3: ...APTER PAGE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 OPERATION 9 6 CLEANING MAINTENANCE PROCEDURES 10 7 TROUBLESHOOTING 11 8 PARTS LISTS 13 9 EXPLODED VIEW 14 10 WIRING DIA...

Страница 4: ...DONE BY PERSONNEL QUALIFIED TO WORK WITH ELECTRICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTI...

Страница 5: ...this or any other LANG appliance must be performed by qualified personnel only Consult your authorized service station directory or call the factory at 1 800 224 LANG 5264 or WWW LANGWORLD COM for th...

Страница 6: ...normally associated with moving it through hallways and doorways 3 3 Un crating The cheese melter will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid R...

Страница 7: ...of the unit in the lower front corner The voltage wattage serial number wire size and clearance specifications are on the data plate This information should be carefully read and understood before pro...

Страница 8: ...model MM36C 3 CLS Cheese melter is shipped from the factory wired for 220 volts 4 3 Phasing All cheese melters are shipped from the factory set up for a single phase service 4 4 Elements Elements for...

Страница 9: ...choice of cooking positions for a variety of applications The top position is very hot and can be used for quick browning and toasting with the heat decreasing at each lower position In order to chan...

Страница 10: ...ater solution Discoloration or heat tint may be removed with any of the following cleaners Penny Bright Copper Bright Du Bois Temp or Past Nu Steel Always apply these cleaners when the unit is cold an...

Страница 11: ...of failure then to the Possible Cause for the items to be checked To test for a possible cause refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures SY...

Страница 12: ...Y PARTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative Possible Cause TEST...

Страница 13: ...06 51 1 14 MM36 Rack 50200 14 1 15 Black Threaded Boot for Metal Toggle Switch 30303 15 1 16 Metal Handle Toggle Switch On On DPDT 30303 14 1 17 Panel Assembly MMCL 191 1 1 18 2 Pole Contactor 30 Amp...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19 WIRING DIAGRAM...

Страница 20: ...ted by the repair Quartz elements are warranted for ninety 90 days from the date of installation II Damage during shipment is to be reported to the carrier is not covered under this warranty and is th...

Отзывы: